Reliability of an ultrasound imaging acquisition procedure for examining osteoarthritis in the first metatarsophalangeal joint

Reliability of an ultrasound imaging acquisition procedure for examining osteoarthritis in the first metatarsophalangeal joint
Reliability of an ultrasound imaging acquisition procedure for examining osteoarthritis in the first metatarsophalangeal joint
Objective: given the ability of ultrasound imaging (USI) to depict tissue-specific morphological changes before the onset of pain and before the point of irreversible structural damage, USI could play a fundamental role in earlier detection and assessment of foot osteoarthritis (OA). Current guidelines require further refinement of anatomical landmarks to establish a standardised imaging procedure to improve interpretability and reproducibility between studies evaluating the first metatarsophalangeal joint (MTPJ). The aims were to develop an USI acquisition procedure and grading system to examine OA features in the first MTPJ and to determine intra-examiner and inter-examiner reliability of a newly developed USI acquisition procedure.

Design: thirty participants with first MTPJ OA confirmed radiographically with the use of the La Trobe Foot Atlas were included. An experienced sonographer applied a newly developed USI procedure to examine the following features: joint effusion, synovial hypertrophy, synovitis, joint space narrowing, osteophytes, and cartilage thickness. A semiquantitative grading system was applied to all features. A continuous measure was also examined for osteophyte size, joint space narrowing, and cartilage thickness. To determine intra-examiner and inter-examiner reliability an experienced radiologist and sonographer applied the developed grading system to the images acquired from two imaging sessions. Intra-examiner and inter-examiner reliability were calculated using intraclass correlation coefficients (ICC).

Results: ICCs for intra-examiner between session reliability ranged from 0.58 to 0.92 for semiquantitative grading and 0.39 to 0.94 for continuous measures. Joint effusion and osteophytes achieved the highest intra-examiner reliability (ICC = 0.78-0.94). ICCs for session one inter-examiner reliability ranged from 0.61 to 1.0 for semiquantitative grading, all continuous measures had an ICC of 1. ICCs for session two inter-examiner reliability ranged from 0.55 to 1.0 for semiquantitative grading and 0.9 to 0.97 for continuous measures. Inter-examiner reliability was good for grading joint effusion (ICC = 0.55-0.62) and was excellent for all other USI features (ICC = 0.77-1.0).

Conclusion: the USI acquisition procedure and grading system are reliable in evaluating first MTPJ osteoarthritis features in participants with radiologically confirmed osteoarthritis. The study will inform the methodological development of an ultrasound atlas for grading the degree of osteoarthritic change in the first MTPJ.
Osteoarthritis, Metatarsophalangeal Joint, Ultrasonography, Foot
1757-1146
Molyneux, Prue
f684713f-6a8e-4304-9fb6-8becd6135536
Bowen, Catherine
fd85c3c5-96d9-49b8-86c6-caa94e1a222b
Ellis, Richard
ae8680a5-5a99-44df-b3ae-7336affc0a09
Rome, Keith
29a0826d-66f7-4ce1-b3e5-c8809cd829bd
Fitzgerald, Kate
72c37fb3-3c2e-4065-962f-e98cd1d0008b
Clark, Phillip
7e0032e3-f1c0-478c-9bc8-20ca360fa57b
Carroll, Matthew
37b7e4cf-8f79-4be0-982c-d125dcf9db52
Molyneux, Prue
f684713f-6a8e-4304-9fb6-8becd6135536
Bowen, Catherine
fd85c3c5-96d9-49b8-86c6-caa94e1a222b
Ellis, Richard
ae8680a5-5a99-44df-b3ae-7336affc0a09
Rome, Keith
29a0826d-66f7-4ce1-b3e5-c8809cd829bd
Fitzgerald, Kate
72c37fb3-3c2e-4065-962f-e98cd1d0008b
Clark, Phillip
7e0032e3-f1c0-478c-9bc8-20ca360fa57b
Carroll, Matthew
37b7e4cf-8f79-4be0-982c-d125dcf9db52

Molyneux, Prue, Bowen, Catherine, Ellis, Richard, Rome, Keith, Fitzgerald, Kate, Clark, Phillip and Carroll, Matthew (2023) Reliability of an ultrasound imaging acquisition procedure for examining osteoarthritis in the first metatarsophalangeal joint. Journal of Foot and Ankle Research, 17 (1). (doi:10.1002/jfa2.12002).

Record type: Article

Abstract

Objective: given the ability of ultrasound imaging (USI) to depict tissue-specific morphological changes before the onset of pain and before the point of irreversible structural damage, USI could play a fundamental role in earlier detection and assessment of foot osteoarthritis (OA). Current guidelines require further refinement of anatomical landmarks to establish a standardised imaging procedure to improve interpretability and reproducibility between studies evaluating the first metatarsophalangeal joint (MTPJ). The aims were to develop an USI acquisition procedure and grading system to examine OA features in the first MTPJ and to determine intra-examiner and inter-examiner reliability of a newly developed USI acquisition procedure.

Design: thirty participants with first MTPJ OA confirmed radiographically with the use of the La Trobe Foot Atlas were included. An experienced sonographer applied a newly developed USI procedure to examine the following features: joint effusion, synovial hypertrophy, synovitis, joint space narrowing, osteophytes, and cartilage thickness. A semiquantitative grading system was applied to all features. A continuous measure was also examined for osteophyte size, joint space narrowing, and cartilage thickness. To determine intra-examiner and inter-examiner reliability an experienced radiologist and sonographer applied the developed grading system to the images acquired from two imaging sessions. Intra-examiner and inter-examiner reliability were calculated using intraclass correlation coefficients (ICC).

Results: ICCs for intra-examiner between session reliability ranged from 0.58 to 0.92 for semiquantitative grading and 0.39 to 0.94 for continuous measures. Joint effusion and osteophytes achieved the highest intra-examiner reliability (ICC = 0.78-0.94). ICCs for session one inter-examiner reliability ranged from 0.61 to 1.0 for semiquantitative grading, all continuous measures had an ICC of 1. ICCs for session two inter-examiner reliability ranged from 0.55 to 1.0 for semiquantitative grading and 0.9 to 0.97 for continuous measures. Inter-examiner reliability was good for grading joint effusion (ICC = 0.55-0.62) and was excellent for all other USI features (ICC = 0.77-1.0).

Conclusion: the USI acquisition procedure and grading system are reliable in evaluating first MTPJ osteoarthritis features in participants with radiologically confirmed osteoarthritis. The study will inform the methodological development of an ultrasound atlas for grading the degree of osteoarthritic change in the first MTPJ.

Text
Journal of Foot and Ankle Research - 2024 - Molyneux - Reliability of an ultrasound imaging acquisition procedure for - Version of Record
Available under License Creative Commons Attribution.
Download (1MB)

More information

Accepted/In Press date: 1 March 2023
Published date: 29 March 2023
Keywords: Osteoarthritis, Metatarsophalangeal Joint, Ultrasonography, Foot

Identifiers

Local EPrints ID: 492104
URI: http://eprints.soton.ac.uk/id/eprint/492104
ISSN: 1757-1146
PURE UUID: 393af20e-2dc3-47d2-bedb-7a798c9b8cee
ORCID for Catherine Bowen: ORCID iD orcid.org/0000-0002-7252-9515

Catalogue record

Date deposited: 16 Jul 2024 17:02
Last modified: 17 Jul 2024 01:37

Export record

Altmetrics

Contributors

Author: Prue Molyneux
Author: Catherine Bowen ORCID iD
Author: Richard Ellis
Author: Keith Rome
Author: Kate Fitzgerald
Author: Phillip Clark
Author: Matthew Carroll

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×