DC link voltage control during sudden load changes in AC microgrids
DC link voltage control during sudden load changes in AC microgrids
Parallel inverters in AC microgrids can achieve accurate power sharing using droop control. However, different grid line impedances will result in different transient power and thus different energy being delivered or absorbed by the inverters during sudden load changes. This might lead the DC link voltage to rise beyond the trip limit causing the inverter to shut down, which reduces the reliability of the whole microgrid. This paper investigates the effect of the mismatch in line impedances on the stability of the DC link voltage during a sudden load changes and proposes a scheme to control the DC link voltage during disturbances. Simulation and experimental results are presented to verify the efficacy of the proposed controller.
76-81
Issa, Walid
539ed2e1-38ee-436c-b7c2-4678fb116f1d
Sharkh, Suleiman
c8445516-dafe-41c2-b7e8-c21e295e56b9
Albadawi, R
755e917c-0337-4427-960e-c1bfb7379a1e
Abusara, Mohammad
4b927b5e-0c68-45bb-8d01-4c22d94ccc7a
Mallick, T. K.
65f62b95-37ca-4c7e-9833-3e46f1cd54db
2017
Issa, Walid
539ed2e1-38ee-436c-b7c2-4678fb116f1d
Sharkh, Suleiman
c8445516-dafe-41c2-b7e8-c21e295e56b9
Albadawi, R
755e917c-0337-4427-960e-c1bfb7379a1e
Abusara, Mohammad
4b927b5e-0c68-45bb-8d01-4c22d94ccc7a
Mallick, T. K.
65f62b95-37ca-4c7e-9833-3e46f1cd54db
Issa, Walid, Sharkh, Suleiman, Albadawi, R, Abusara, Mohammad and Mallick, T. K.
(2017)
DC link voltage control during sudden load changes in AC microgrids.
In Proceedings of the IEEE International Symposium on Industrial Electronics (ISIE).
.
(doi:10.1109/ISIE.2017.8001226).
Record type:
Conference or Workshop Item
(Paper)
Abstract
Parallel inverters in AC microgrids can achieve accurate power sharing using droop control. However, different grid line impedances will result in different transient power and thus different energy being delivered or absorbed by the inverters during sudden load changes. This might lead the DC link voltage to rise beyond the trip limit causing the inverter to shut down, which reduces the reliability of the whole microgrid. This paper investigates the effect of the mismatch in line impedances on the stability of the DC link voltage during a sudden load changes and proposes a scheme to control the DC link voltage during disturbances. Simulation and experimental results are presented to verify the efficacy of the proposed controller.
Text
DC_link_voltage_control_during_sudden_load_changes_in_AC_microgrids
- Version of Record
Restricted to Repository staff only
Request a copy
More information
Published date: 2017
Identifiers
Local EPrints ID: 493807
URI: http://eprints.soton.ac.uk/id/eprint/493807
PURE UUID: 7fb87281-a44e-48ed-bca7-cdb4aebfae34
Catalogue record
Date deposited: 12 Sep 2024 17:27
Last modified: 13 Sep 2024 01:34
Export record
Altmetrics
Contributors
Author:
Walid Issa
Author:
R Albadawi
Author:
Mohammad Abusara
Author:
T. K. Mallick
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics