The University of Southampton
University of Southampton Institutional Repository

Enhancing performance of thermoelectric coolers through the application of distributed control

Enhancing performance of thermoelectric coolers through the application of distributed control
Enhancing performance of thermoelectric coolers through the application of distributed control
The primary drawback of thermoelectric coolers (TECs) for electronics cooling applications is their thermodynamic inefficiency due to material limitations. The present work considers a control strategy to improve the overall coefficient of performance in an engineering system instead of addressing material shortcomings. Typical TECs are composed of several individual thermocouples that are powered in series and remove heat in parallel. If one of the numerous thermocouples is powered, all the thermocouples receive the same power whether or not they are needed. The fact that chips heat nonuniformly provides an opportunity for performance enhancement, by sensing and controlling the power to individual couples within the device. The current work presents evidence that applying distributed control to TEC operation can realize appreciable improvement in performance. Compared to monolithic cooling devices, a distributed control strategy can realize a factor of 2 increase in performance for the device studied. Additionally, this type of control can be used in conjunction with many of the existing material-based research initiatives to further compound the benefits.
1521-3331
330-336
Harvey, R.D.
03082bd9-41aa-43e6-a451-7e4416a913da
Walker, D.G.
b0015cd4-fc53-42ed-ad56-0340b0aaf897
Frampton, K.D.
dac17a56-41de-4b0e-b55d-1c5828e780d1
Harvey, R.D.
03082bd9-41aa-43e6-a451-7e4416a913da
Walker, D.G.
b0015cd4-fc53-42ed-ad56-0340b0aaf897
Frampton, K.D.
dac17a56-41de-4b0e-b55d-1c5828e780d1

Harvey, R.D., Walker, D.G. and Frampton, K.D. (2007) Enhancing performance of thermoelectric coolers through the application of distributed control. IEEE Transactions on Components and Packaging Technologies, 30 (2), 330-336. (doi:10.1109/TCAPT.2007.898376).

Record type: Article

Abstract

The primary drawback of thermoelectric coolers (TECs) for electronics cooling applications is their thermodynamic inefficiency due to material limitations. The present work considers a control strategy to improve the overall coefficient of performance in an engineering system instead of addressing material shortcomings. Typical TECs are composed of several individual thermocouples that are powered in series and remove heat in parallel. If one of the numerous thermocouples is powered, all the thermocouples receive the same power whether or not they are needed. The fact that chips heat nonuniformly provides an opportunity for performance enhancement, by sensing and controlling the power to individual couples within the device. The current work presents evidence that applying distributed control to TEC operation can realize appreciable improvement in performance. Compared to monolithic cooling devices, a distributed control strategy can realize a factor of 2 increase in performance for the device studied. Additionally, this type of control can be used in conjunction with many of the existing material-based research initiatives to further compound the benefits.

This record has no associated files available for download.

More information

Published date: June 2007

Identifiers

Local EPrints ID: 49403
URI: http://eprints.soton.ac.uk/id/eprint/49403
ISSN: 1521-3331
PURE UUID: c2fff99a-a982-440f-b0b6-5f3d61ca80ca

Catalogue record

Date deposited: 09 Nov 2007
Last modified: 15 Mar 2024 09:55

Export record

Altmetrics

Contributors

Author: R.D. Harvey
Author: D.G. Walker
Author: K.D. Frampton

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×