READ ME File For 'Single-cell electro-mechanical shear flow deformability cytometry' Dataset DOI: https://doi.org/10.5258/SOTON/D3151 ReadMe Author: Junyu Chen, University of Southampton, https://orcid.org/my-orcid?orcid=0009-0006-9975-7493 This dataset supports the publication: AUTHORS: Junyu Chen CONTRIBUTORS:Xueping Zou, Daniel C. Spencer and Hywel Morgan. TITLE: Single-cell electro-mechanical shear flow deformability cytometry JOURNAL: Nature Microsystems and Nanoengineering This dataset contains data for the figures The figures are as follows: Figure 1 Density plots of electrical deformability (c) and electrical opacity (d) as a function of electrical diameter for HL60 cells Figure 2 Figure 2 (c) Sensitivity plots for vertical impedance Z1 and (d) lateral impedance Z2 as a function of the deformation index (major/minor axis) for three different sizes of particles. (e) Electrical deformability (Z1/Z2) as a function of the deformation index for three different sizes of particles. Figure 3 Osmotic data,information on the data is contained in the first sheet (named "Information") Figure 4 GA fixation data,information on the data is contained in the first sheet (named "Information") Figure 5 CytoD data,information on the data is contained in the first sheet (named "Information") Figure 6 Correlation between the Electrical Deformability (ED) and Optical Deformability (OD) for HL60 cells (Control, Glutaraldehyde (GA) and CytoD treated) together with beads. Supplementary Figure 2 (b) Magnitude of the vertical impedance Z1 (red) and lateral impedance Z2 (blue) as a function of vertical position in the channel (z-axis) for a 5µm diameter particle. (c) as for (b) but for a 12µm diameter particle. Supplementary Figure 3 (b) Histogram showing the experimentally measured velocities of a mixture of 5 µm and 10µm diameter beads (suspended in PBS) at a volumetric flow rate of 5µl/min (approximately 3,000 particles); (c) Histogram for the same particles suspended in 0.5%v/v MC-PBS at a flow rate of 5µl/min. Supplementary Figure 4 (a). Electrical deformability of GA fixed cell versus electrical diameter at a flow rate of 10μl/min. (b) Dose-response curve and Hill equation fit for electrical deformability at a flow rate of 10μl/min giving EC50 = 0.0012% v/v. Supplementary Figure 5 (a). Electrical deformability of CytoD treated HL60 cells at a flow rate of 10μl/min. (b) Dose-response plot of electrical deformability at a flow rate of 10μl/min giving EC50 = 11nM. Date that the file was created: 27th June 2024