Limits and opportunities for miniaturizing ultrasonic surgical devices based on a Langevin transducer

Limits and opportunities for miniaturizing ultrasonic surgical devices based on a Langevin transducer
Limits and opportunities for miniaturizing ultrasonic surgical devices based on a Langevin transducer
Minimally invasive surgery offers opportunities for reduced morbidities, faster postoperative recovery, and reduced costs, and is a major focus of surgical device innovation. For ultrasonic surgical devices, which offer benefits of high precision, low force, and tissue selectivity in surgical procedures, there exist laparoscopic ultrasonic shears for minimally invasive surgeries that combine tissue cutting with vessel hemostasis and sealing functions. Another approach to laparoscopy that could enable new procedures, and increase the sites of surgeries that could be reached by an ultrasonic device, involves integrating a miniature ultrasonic tool with a flexible surgical robot. However, miniaturization presents challenges in delivering the ultrasonic vibrational energy required to cut hard and soft tissues, partly due to the concomitant small volume of piezoelectric material. This article aims to provide insights into the trade-offs between transducer size, volume of piezoceramic material, resonance frequency, and the achievable displacement amplitude of devices that, consistent with current ultrasonic surgical tools, are based on a bolted Langevin transducer (BLT) and tip. Different configurations of BLTs are studied, including a cascaded version, simple bar versions, and BLTs with different front mass geometries. Results show that a BLT with a larger number of piezoceramic rings exhibits a higher coupling coefficient keff but with the compromise of a lower mechanical Q and stronger nonlinear response at increasing excitation levels. Displacement amplitude is reduced considerably when a BLT is excited at a higher harmonic, where the PZT rings are maintained at a nodal plane, and the resonance frequency shift at increasing excitation levels increases significantly. The electromechanical and dynamic characteristics of a cascaded transducer excited in its third longitudinal mode (L3) are almost equivalent to a much shorter version of a BLT driven at the same frequency but in its first longitudinal mode (L1), showing that a cascaded BLT can be a realistic proxy for studying the dynamics of small BLT devices. A new figure of merit is proposed that is the product of Q, keff2, and gain, which accounts for the gain of cylindrical BLTs which is shown not to be unity. It also proves effective as it incorporates the key factors affecting the achievable displacement amplitude of a BLT, including for BLTs with gain profiles in the front mass. The order of highest to lowest amplitude of a series of six gain-profile BLTs matches the order estimated by the figure of merit. It is shown that a BLT with a stepped profile front mass can achieve displacement that has the potential to cut hard or soft tissue and exhibits the smallest shifts in resonance frequency at increasing excitation levels.
0885-3010
2543-2553
Li, Xuan
ed01c0d5-68e0-4abe-8642-5b9ebf153314
Stritch, Thomas
479e5a0a-8dae-4c6c-9b5d-52c3372d3876
Manley, Kevin
f23b3451-5048-47f9-976b-79506dbbf18a
Lucas, Margaret
896f4b80-c53c-43d2-bdc5-c76e80ab4a46
Li, Xuan
ed01c0d5-68e0-4abe-8642-5b9ebf153314
Stritch, Thomas
479e5a0a-8dae-4c6c-9b5d-52c3372d3876
Manley, Kevin
f23b3451-5048-47f9-976b-79506dbbf18a
Lucas, Margaret
896f4b80-c53c-43d2-bdc5-c76e80ab4a46

Li, Xuan, Stritch, Thomas, Manley, Kevin and Lucas, Margaret (2021) Limits and opportunities for miniaturizing ultrasonic surgical devices based on a Langevin transducer. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 68 (7), 2543-2553. (doi:10.1109/TUFFC.2021.3065207).

Record type: Article

Abstract

Minimally invasive surgery offers opportunities for reduced morbidities, faster postoperative recovery, and reduced costs, and is a major focus of surgical device innovation. For ultrasonic surgical devices, which offer benefits of high precision, low force, and tissue selectivity in surgical procedures, there exist laparoscopic ultrasonic shears for minimally invasive surgeries that combine tissue cutting with vessel hemostasis and sealing functions. Another approach to laparoscopy that could enable new procedures, and increase the sites of surgeries that could be reached by an ultrasonic device, involves integrating a miniature ultrasonic tool with a flexible surgical robot. However, miniaturization presents challenges in delivering the ultrasonic vibrational energy required to cut hard and soft tissues, partly due to the concomitant small volume of piezoelectric material. This article aims to provide insights into the trade-offs between transducer size, volume of piezoceramic material, resonance frequency, and the achievable displacement amplitude of devices that, consistent with current ultrasonic surgical tools, are based on a bolted Langevin transducer (BLT) and tip. Different configurations of BLTs are studied, including a cascaded version, simple bar versions, and BLTs with different front mass geometries. Results show that a BLT with a larger number of piezoceramic rings exhibits a higher coupling coefficient keff but with the compromise of a lower mechanical Q and stronger nonlinear response at increasing excitation levels. Displacement amplitude is reduced considerably when a BLT is excited at a higher harmonic, where the PZT rings are maintained at a nodal plane, and the resonance frequency shift at increasing excitation levels increases significantly. The electromechanical and dynamic characteristics of a cascaded transducer excited in its third longitudinal mode (L3) are almost equivalent to a much shorter version of a BLT driven at the same frequency but in its first longitudinal mode (L1), showing that a cascaded BLT can be a realistic proxy for studying the dynamics of small BLT devices. A new figure of merit is proposed that is the product of Q, keff2, and gain, which accounts for the gain of cylindrical BLTs which is shown not to be unity. It also proves effective as it incorporates the key factors affecting the achievable displacement amplitude of a BLT, including for BLTs with gain profiles in the front mass. The order of highest to lowest amplitude of a series of six gain-profile BLTs matches the order estimated by the figure of merit. It is shown that a BLT with a stepped profile front mass can achieve displacement that has the potential to cut hard or soft tissue and exhibits the smallest shifts in resonance frequency at increasing excitation levels.

Text
Limits_and_Opportunities_for_Miniaturizing_Ultrasonic_Surgical_Devices_Based_on_a_Langevin_Transducer - Version of Record
Available under License Creative Commons Attribution.
Download (5MB)

More information

Accepted/In Press date: 7 March 2021
Published date: 10 March 2021

Identifiers

Local EPrints ID: 497467
URI: http://eprints.soton.ac.uk/id/eprint/497467
ISSN: 0885-3010
PURE UUID: 83f81618-30a2-4edf-abd1-d0d4a3718cc0
ORCID for Xuan Li: ORCID iD orcid.org/0000-0002-5655-8631

Catalogue record

Date deposited: 23 Jan 2025 17:36
Last modified: 24 Jan 2025 03:14

Export record

Altmetrics

Contributors

Author: Xuan Li ORCID iD
Author: Thomas Stritch
Author: Kevin Manley
Author: Margaret Lucas

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×