The University of Southampton
University of Southampton Institutional Repository

An adaptive thresholding algorithm for porosity measurement of additively manufactured metal test samples via X-ray computed tomography

An adaptive thresholding algorithm for porosity measurement of additively manufactured metal test samples via X-ray computed tomography
An adaptive thresholding algorithm for porosity measurement of additively manufactured metal test samples via X-ray computed tomography
If additively manufactured metal parts are to be used as performance critical components in the aerospace and other high-value industries, then non-destructive methods for measuring the porosity of these parts are required; X-ray computed tomography (XCT) is a promising instrument for this measurement task. One disadvantage of using XCT for this purpose is the presence of artefacts in XCT data of high-density materials (aluminium, titanium, steel and Inconel). These artefacts are problematic for segmentation algorithms that are required for porosity measurement. In this work we propose an adaptive thresholding algorithm for segmenting XCT data. The algorithm is specifically designed to overcome the influence of beam hardening (cupping) artefacts that are typically observed when XCT scanning high-density metal parts. The algorithm is also designed to have as few as possible user-defined settings in order to minimise the influence the user has on the segmentation result. The results show that the algorithm is able to segment small voids in low contrast-to-noise ratio XCT data and that the algorithm is robust to cupping artefacts. The accuracy of the method is evaluated for a set of Inconel cubes approximately 10 mm × 10 mm × 10 mm in size (H × W × D), reference porosity measurements are made using Archimedes’ principle. The mean error and standard deviation of the XCT percentage porosity measurements evaluated by four different users are found to be: −0.38 ± 0.09%, 0.09 ± 0.09% and −0.23 ± 0.22% for samples with bulk porosities of 0.23 ± 0.28%, 1.42 ± 0.28% and 3.00 ± 0.28%, respectively.
2214-8604
Lifton, Joseph
9be501ec-2742-4ab6-8a5a-996c5b7c23ae
Lifton, Joseph
9be501ec-2742-4ab6-8a5a-996c5b7c23ae

Lifton, Joseph (2021) An adaptive thresholding algorithm for porosity measurement of additively manufactured metal test samples via X-ray computed tomography. Additive Manufacturing, 39, [101899]. (doi:10.1016/j.addma.2021.101899).

Record type: Article

Abstract

If additively manufactured metal parts are to be used as performance critical components in the aerospace and other high-value industries, then non-destructive methods for measuring the porosity of these parts are required; X-ray computed tomography (XCT) is a promising instrument for this measurement task. One disadvantage of using XCT for this purpose is the presence of artefacts in XCT data of high-density materials (aluminium, titanium, steel and Inconel). These artefacts are problematic for segmentation algorithms that are required for porosity measurement. In this work we propose an adaptive thresholding algorithm for segmenting XCT data. The algorithm is specifically designed to overcome the influence of beam hardening (cupping) artefacts that are typically observed when XCT scanning high-density metal parts. The algorithm is also designed to have as few as possible user-defined settings in order to minimise the influence the user has on the segmentation result. The results show that the algorithm is able to segment small voids in low contrast-to-noise ratio XCT data and that the algorithm is robust to cupping artefacts. The accuracy of the method is evaluated for a set of Inconel cubes approximately 10 mm × 10 mm × 10 mm in size (H × W × D), reference porosity measurements are made using Archimedes’ principle. The mean error and standard deviation of the XCT percentage porosity measurements evaluated by four different users are found to be: −0.38 ± 0.09%, 0.09 ± 0.09% and −0.23 ± 0.22% for samples with bulk porosities of 0.23 ± 0.28%, 1.42 ± 0.28% and 3.00 ± 0.28%, respectively.

This record has no associated files available for download.

More information

Published date: 15 February 2021

Identifiers

Local EPrints ID: 498007
URI: http://eprints.soton.ac.uk/id/eprint/498007
ISSN: 2214-8604
PURE UUID: 3efa84ae-66fa-4d08-90ea-44d9ab3a05cb
ORCID for Joseph Lifton: ORCID iD orcid.org/0000-0002-8716-1055

Catalogue record

Date deposited: 05 Feb 2025 18:19
Last modified: 06 Feb 2025 03:12

Export record

Altmetrics

Contributors

Author: Joseph Lifton ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×