The University of Southampton
University of Southampton Institutional Repository

Variability of lung function in primary ciliary dyskinesia: longitudinal analysis from the PROVALF-PCD cohort

Variability of lung function in primary ciliary dyskinesia: longitudinal analysis from the PROVALF-PCD cohort
Variability of lung function in primary ciliary dyskinesia: longitudinal analysis from the PROVALF-PCD cohort
Background: the extent to which changes in lung function are due to natural variability in patients with primary ciliary dyskinesia (PCD) is unknown. We aimed to assess intra-individual variability in forced expiratory volume in 1s (FEV1) derived from spirometry to define the extent to which the observed changes were due to test variability in clinically stable PCD patients.

Methods: PROVALF-PCD is a large international prospective cohort conducted in 2017-2019. We included patients ≥5 years who were clinically stable in ≥2 consecutive visits and provided spirometry-derived lung function measurements. To calculate the upper limit of normal (ULN), we fitted an unadjusted multilevel mixed effect model, and to determine the absolute change in FEV1 z-scores, we calculated the coefficient of repeatability (CR). We performed sensitivity analyses by stratifying relative change by age (adults versus children), number of measurements (≥4), and time between measurements (<4 months apart).

Results: we included 252 participants from 12 countries with confirmed or highly likely PCD. We included 1028 FEV1 measurements from patients in stable state. The ULN for relative change between two measurements of FEV1 was 25%. Test variability remained high in all sensitivity analyses. The CR was 1.88 FEV1 z-score.

Conclusions: changes in intra-individual FEV1 between visits greater than 25% in stable PCD patients lie beyond the expected test variability and therefore could be considered physiologically relevant. These findings inform the selection of endpoints for pulmonary intervention trials in PCD, as they suggest FEV1 is not a sensitive test for monitoring lung health in PCD.
2312-0541
Zhang, Kewei
7285abed-cd11-48bb-935b-51b7c36f9ff5
Kant, Avni
49227140-e667-4d35-995b-af69af3201bc
Boon, Mieke
ac53bd13-9cb8-4810-8fb7-fb693f1874c4
Rubbo, Bruna
dc31cd48-3d84-41ab-a8b8-351c9914dca4
et al.
Zhang, Kewei
7285abed-cd11-48bb-935b-51b7c36f9ff5
Kant, Avni
49227140-e667-4d35-995b-af69af3201bc
Boon, Mieke
ac53bd13-9cb8-4810-8fb7-fb693f1874c4
Rubbo, Bruna
dc31cd48-3d84-41ab-a8b8-351c9914dca4

Zhang, Kewei, Kant, Avni and Boon, Mieke , et al. (2024) Variability of lung function in primary ciliary dyskinesia: longitudinal analysis from the PROVALF-PCD cohort. ERJ Open Research. (In Press)

Record type: Meeting abstract

Abstract

Background: the extent to which changes in lung function are due to natural variability in patients with primary ciliary dyskinesia (PCD) is unknown. We aimed to assess intra-individual variability in forced expiratory volume in 1s (FEV1) derived from spirometry to define the extent to which the observed changes were due to test variability in clinically stable PCD patients.

Methods: PROVALF-PCD is a large international prospective cohort conducted in 2017-2019. We included patients ≥5 years who were clinically stable in ≥2 consecutive visits and provided spirometry-derived lung function measurements. To calculate the upper limit of normal (ULN), we fitted an unadjusted multilevel mixed effect model, and to determine the absolute change in FEV1 z-scores, we calculated the coefficient of repeatability (CR). We performed sensitivity analyses by stratifying relative change by age (adults versus children), number of measurements (≥4), and time between measurements (<4 months apart).

Results: we included 252 participants from 12 countries with confirmed or highly likely PCD. We included 1028 FEV1 measurements from patients in stable state. The ULN for relative change between two measurements of FEV1 was 25%. Test variability remained high in all sensitivity analyses. The CR was 1.88 FEV1 z-score.

Conclusions: changes in intra-individual FEV1 between visits greater than 25% in stable PCD patients lie beyond the expected test variability and therefore could be considered physiologically relevant. These findings inform the selection of endpoints for pulmonary intervention trials in PCD, as they suggest FEV1 is not a sensitive test for monitoring lung health in PCD.

Text
Provalf natural variability LF_ERJOR_R1 - Accepted Manuscript
Restricted to Repository staff only
Request a copy

More information

Accepted/In Press date: 10 December 2024

Identifiers

Local EPrints ID: 498197
URI: http://eprints.soton.ac.uk/id/eprint/498197
ISSN: 2312-0541
PURE UUID: 287b963a-c649-44e2-8b61-84f8476bf138
ORCID for Bruna Rubbo: ORCID iD orcid.org/0000-0002-1629-8601

Catalogue record

Date deposited: 12 Feb 2025 17:42
Last modified: 13 Feb 2025 02:48

Export record

Contributors

Author: Kewei Zhang
Author: Avni Kant
Author: Mieke Boon
Author: Bruna Rubbo ORCID iD
Corporate Author: et al.

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×