A parametric study of a platinum ruthenium anode in a direct borohydride fuel cell
A parametric study of a platinum ruthenium anode in a direct borohydride fuel cell
Data on the performance of a direct borohydride fuel cell (DBFC) equipped with an anion exchange membrane, a Pt-Ru/C anode and a Pt/C cathode are reported. The effect of oxidant (air or oxygen), borohydride and electrolyte concentrations, temperature and anode solution flow rate is described. The DBFC gives power densities of 200 and 145 mW cm-2 using ambient oxygen and air cathodes respectively at medium temperatures (60 °C). The performance of the DBFC is very good at low temperatures (ca. 30 °C) using modest catalyst loadings of 1 mg cm-2 for anode and cathode. Preliminary data indicate that the cell will be stable over significant operating times.
Anion exchange membrane, Direct borohydride fuel cell, Fuel cell, Platinum ruthenium anode
1085-1091
Duteanu, N.
cad44aea-feee-41e8-8d41-957c7dc78da5
Vlachogiannopoulos, G.
f9a892a6-8486-4a1c-9b5e-23dbd7d555da
Shivhare, M. R.
1fda09d8-532c-41ed-a5aa-e5461e56af85
Yu, E. H.
28e47863-4b50-4821-b80b-71fb5a2edef2
Scott, Keith
38909157-296d-4fe7-a245-1b98e1fee913
September 2007
Duteanu, N.
cad44aea-feee-41e8-8d41-957c7dc78da5
Vlachogiannopoulos, G.
f9a892a6-8486-4a1c-9b5e-23dbd7d555da
Shivhare, M. R.
1fda09d8-532c-41ed-a5aa-e5461e56af85
Yu, E. H.
28e47863-4b50-4821-b80b-71fb5a2edef2
Scott, Keith
38909157-296d-4fe7-a245-1b98e1fee913
Duteanu, N., Vlachogiannopoulos, G., Shivhare, M. R., Yu, E. H. and Scott, Keith
(2007)
A parametric study of a platinum ruthenium anode in a direct borohydride fuel cell.
Journal of Applied Electrochemistry, 37 (9), .
(doi:10.1007/s10800-007-9360-y).
Abstract
Data on the performance of a direct borohydride fuel cell (DBFC) equipped with an anion exchange membrane, a Pt-Ru/C anode and a Pt/C cathode are reported. The effect of oxidant (air or oxygen), borohydride and electrolyte concentrations, temperature and anode solution flow rate is described. The DBFC gives power densities of 200 and 145 mW cm-2 using ambient oxygen and air cathodes respectively at medium temperatures (60 °C). The performance of the DBFC is very good at low temperatures (ca. 30 °C) using modest catalyst loadings of 1 mg cm-2 for anode and cathode. Preliminary data indicate that the cell will be stable over significant operating times.
This record has no associated files available for download.
More information
Published date: September 2007
Keywords:
Anion exchange membrane, Direct borohydride fuel cell, Fuel cell, Platinum ruthenium anode
Identifiers
Local EPrints ID: 498536
URI: http://eprints.soton.ac.uk/id/eprint/498536
ISSN: 0021-891X
PURE UUID: fb969912-3ea6-4e97-93a0-6627ed9e301f
Catalogue record
Date deposited: 20 Feb 2025 18:13
Last modified: 21 Feb 2025 03:16
Export record
Altmetrics
Contributors
Author:
N. Duteanu
Author:
G. Vlachogiannopoulos
Author:
M. R. Shivhare
Author:
E. H. Yu
Author:
Keith Scott
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics