We introduce a fully informative distribution network phasor measurement unit (FI-DPMU), that is capable of performing a simultaneous estimation of phasor dynamics and harmonic components. This is in contrast with current state-of-the-art devices, that only provide information about the fundamental component of voltages/currents—by discriminating or filtering-out their harmonic content. The FI-DPMU hence represents a significant economical solution, since it bypasses the need to deploy power quality analyzers to retrieve full information about the network. To validate the accuracy of the FI-DPMU, we performed a hardware-in-the-loop implementation to emulate a distribution network that is subject to abrupt frequency variations and high harmonic distortion. The tests demonstrate that the FI-DPMU satisfies the standards of distribution network phasor measurement units (DPMUs), providing a real-time fast Fourier transform (FFT) as additional feature. Experimental results show a comparison between FI-DPMU measurement data with the information provided by a commercial DPMU.
102575-102585
Pacheco-Cherrez, David S.
ea482515-1bd5-4d41-ba0b-76f456e7a9d7
Mayo-Maldonado, Jonathan C.
c7321b60-3130-43f4-89f4-f12ac5b2f822
Escobar, Gerardo
9d5b1954-920f-46b6-83a3-fc61eed024f2
Valdez-Resendiz, Jesus E.
e54b37af-f112-4b86-b953-1b84b4675ecc
Guillen, Daniel
c07e8c31-c78a-494e-98de-69baf845afa5
21 September 2022
Pacheco-Cherrez, David S.
ea482515-1bd5-4d41-ba0b-76f456e7a9d7
Mayo-Maldonado, Jonathan C.
c7321b60-3130-43f4-89f4-f12ac5b2f822
Escobar, Gerardo
9d5b1954-920f-46b6-83a3-fc61eed024f2
Valdez-Resendiz, Jesus E.
e54b37af-f112-4b86-b953-1b84b4675ecc
Guillen, Daniel
c07e8c31-c78a-494e-98de-69baf845afa5
Pacheco-Cherrez, David S., Mayo-Maldonado, Jonathan C., Escobar, Gerardo, Valdez-Resendiz, Jesus E. and Guillen, Daniel
(2022)
A fully informative phasor measurement unit for distribution networks with harmonic distortion.
IEEE Access, 10, .
(doi:10.1109/ACCESS.2022.3208285).
Abstract
We introduce a fully informative distribution network phasor measurement unit (FI-DPMU), that is capable of performing a simultaneous estimation of phasor dynamics and harmonic components. This is in contrast with current state-of-the-art devices, that only provide information about the fundamental component of voltages/currents—by discriminating or filtering-out their harmonic content. The FI-DPMU hence represents a significant economical solution, since it bypasses the need to deploy power quality analyzers to retrieve full information about the network. To validate the accuracy of the FI-DPMU, we performed a hardware-in-the-loop implementation to emulate a distribution network that is subject to abrupt frequency variations and high harmonic distortion. The tests demonstrate that the FI-DPMU satisfies the standards of distribution network phasor measurement units (DPMUs), providing a real-time fast Fourier transform (FFT) as additional feature. Experimental results show a comparison between FI-DPMU measurement data with the information provided by a commercial DPMU.
Text
A_Fully_Informative_Phasor_Measurement_Unit_for_Distribution_Networks_With_Harmonic_Distortion
- Version of Record
More information
Accepted/In Press date: 12 September 2022
Published date: 21 September 2022
Identifiers
Local EPrints ID: 500133
URI: http://eprints.soton.ac.uk/id/eprint/500133
ISSN: 2169-3536
PURE UUID: 344d94b4-164d-473e-8701-c6f951b32049
Catalogue record
Date deposited: 15 Apr 2025 17:20
Last modified: 16 Apr 2025 02:20
Export record
Altmetrics
Contributors
Author:
David S. Pacheco-Cherrez
Author:
Jonathan C. Mayo-Maldonado
Author:
Gerardo Escobar
Author:
Jesus E. Valdez-Resendiz
Author:
Daniel Guillen
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics