The University of Southampton
University of Southampton Institutional Repository

Reliability of measuring critical knee flexion angle during single leg squat using silicon coachtm in recreational females

Reliability of measuring critical knee flexion angle during single leg squat using silicon coachtm in recreational females
Reliability of measuring critical knee flexion angle during single leg squat using silicon coachtm in recreational females
Movement dysfunction resulting in a knee valgus position during weight bearing activity is associated with increased risk of Anterior Cruciate Ligament injury and Patellofemoral Pain Syndrome especially in young active females. In clinical practice determining the critical knee flexion angle (CKFA) during a single leg squat (SLS) test is used to assess this dysfunction, yet its reliability is unknown. This study aimed to determine rater agreement in determining the presence of knee valgus movement (yes/no) during a SLS test in recreational females (n = 16, age 24.3 ±7.9 yrs, height 165.7±4.8m, mass 62.5±6.4kg) and the intra and inter-rater reliability of measuring CKFA using SiliconCoach™. Three experienced physiotherapists viewed 48 randomised SLS test videos. One physiotherapist repeated the viewing for test-retest analysis. Test-retest agreement for rating SLS test was acceptable (weighted kappa (k) = 0.667). Inter-rater agreement was moderate to substantial (weighted k = 0.284–0.613). Intra-rater reliability of CKFA was acceptable for all three raters (ICC>0.6). Inter-rater absolute reliability was below 5% of the mean CKFA (SEM 4.26 degrees). As previous research reports intra-rater agreement is better than inter-rater agreement when assessing movement dysfunction during functional activity via visual rating. Intra-rater within session and between session reliability for measuring the CKFA using SiliconCoach™ was acceptable and better than inter-rater reliability. Further research is needed to assess the concurrent and construct validity of the protocols used in this study. It is recommended that qualitative research be performed to identify factors that affect physiotherapist's rating of functional activities.
1358-992X
66
Sparkes, V.
d0b168dd-68e6-44e4-be40-f0e3a218be02
Brophy, R.
74e3c296-5c25-467f-81a4-4e4242b5be40
Sheeran, L.
ad753e79-56c8-483f-aae5-dd992496bee2
Sparkes, V.
d0b168dd-68e6-44e4-be40-f0e3a218be02
Brophy, R.
74e3c296-5c25-467f-81a4-4e4242b5be40
Sheeran, L.
ad753e79-56c8-483f-aae5-dd992496bee2

Sparkes, V., Brophy, R. and Sheeran, L. (2013) Reliability of measuring critical knee flexion angle during single leg squat using silicon coachtm in recreational females. Orthopaedic Proceedings, 95B, 66.

Record type: Article

Abstract

Movement dysfunction resulting in a knee valgus position during weight bearing activity is associated with increased risk of Anterior Cruciate Ligament injury and Patellofemoral Pain Syndrome especially in young active females. In clinical practice determining the critical knee flexion angle (CKFA) during a single leg squat (SLS) test is used to assess this dysfunction, yet its reliability is unknown. This study aimed to determine rater agreement in determining the presence of knee valgus movement (yes/no) during a SLS test in recreational females (n = 16, age 24.3 ±7.9 yrs, height 165.7±4.8m, mass 62.5±6.4kg) and the intra and inter-rater reliability of measuring CKFA using SiliconCoach™. Three experienced physiotherapists viewed 48 randomised SLS test videos. One physiotherapist repeated the viewing for test-retest analysis. Test-retest agreement for rating SLS test was acceptable (weighted kappa (k) = 0.667). Inter-rater agreement was moderate to substantial (weighted k = 0.284–0.613). Intra-rater reliability of CKFA was acceptable for all three raters (ICC>0.6). Inter-rater absolute reliability was below 5% of the mean CKFA (SEM 4.26 degrees). As previous research reports intra-rater agreement is better than inter-rater agreement when assessing movement dysfunction during functional activity via visual rating. Intra-rater within session and between session reliability for measuring the CKFA using SiliconCoach™ was acceptable and better than inter-rater reliability. Further research is needed to assess the concurrent and construct validity of the protocols used in this study. It is recommended that qualitative research be performed to identify factors that affect physiotherapist's rating of functional activities.

This record has no associated files available for download.

More information

Published date: 1 March 2013

Identifiers

Local EPrints ID: 501569
URI: http://eprints.soton.ac.uk/id/eprint/501569
ISSN: 1358-992X
PURE UUID: 6d2fe1dc-ab42-4ff0-95f5-ee4b79b3908f
ORCID for L. Sheeran: ORCID iD orcid.org/0000-0002-1502-764X

Catalogue record

Date deposited: 03 Jun 2025 17:08
Last modified: 16 Aug 2025 02:17

Export record

Contributors

Author: V. Sparkes
Author: R. Brophy
Author: L. Sheeran ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×