The University of Southampton
University of Southampton Institutional Repository

Performance enhancement of an Ag–Au bimetallic SPR sensor: a theoretical and experimental study

Performance enhancement of an Ag–Au bimetallic SPR sensor: a theoretical and experimental study
Performance enhancement of an Ag–Au bimetallic SPR sensor: a theoretical and experimental study
Ag–Au bimetallic surface plasmon resonance (SPR) sensors operating in the Kretschmann configuration were investigated by numerical modeling and experiment. While Ag-based sensors have good sensitivity, they suffer from poor stability, and the addition of an Au capping layer offers improved chemical resistance and reliable analyte bonding via thiol–gold interactions. Sensors were evaluated with an Ag–Au combined thickness of 50 nm but different thickness ratios, and SPR reflectivity curves were obtained for 632.8 nm wavelength light incident over a range of angles. Numerical modeling using the transfer matrix method showed the SPR response improving as Au thickness decreased, giving the best results for 45 nm of Ag and 5 nm of Au. Experimental characterization of fabricated Ag–Au bimetallic sensors was carried out with a custom SPR testbed. Performance parameters, including minimum reflectivity, full-width at half-maximum (FWHM), stability, and sensitivity were measured and the results were compared to those of single-layer Ag and Au sensors. A 5 nm Au coating was unable to preserve stable bimetallic sensor performance; however, increasing the Au thickness to 10 nm was sufficient to protect the Ag sensing layer, allowing only a small variation in the minimum reflectivity and FWHM when exposed to analytes for multiple hours. The sensitivity of the single-layer Ag, bimetallic Ag–Au, and Au sensors was measured as 3041%/refractive index unit (RIU), 1817%/RIU, and 1229%/RIU, respectively. The sensitivity of the thickness-optimized bimetallic layer was ∼1.5× that of the single-layer Au sensor.
1930-0395
10420-10428
Babu, Roshni
fe7dbe92-1f6b-44e7-94de-4321ff68284a
Colenso, Hamish
859d7b69-2e72-4885-8167-5331b5695a33
Gouws, Gideon
d6ed507f-ab8c-47f6-9d6d-c59fa3789c47
Auguié, Baptiste
b8622fa1-d7fa-4aa1-ab90-f07f1662eb62
Moore, Ciaran
094f1ba8-6f62-44e2-b0a8-faa8798d7169
Babu, Roshni
fe7dbe92-1f6b-44e7-94de-4321ff68284a
Colenso, Hamish
859d7b69-2e72-4885-8167-5331b5695a33
Gouws, Gideon
d6ed507f-ab8c-47f6-9d6d-c59fa3789c47
Auguié, Baptiste
b8622fa1-d7fa-4aa1-ab90-f07f1662eb62
Moore, Ciaran
094f1ba8-6f62-44e2-b0a8-faa8798d7169

Babu, Roshni, Colenso, Hamish, Gouws, Gideon, Auguié, Baptiste and Moore, Ciaran (2023) Performance enhancement of an Ag–Au bimetallic SPR sensor: a theoretical and experimental study. IEEE SENSORS, 23 (10), 10420-10428. (doi:10.1109/JSEN.2023.3265896).

Record type: Article

Abstract

Ag–Au bimetallic surface plasmon resonance (SPR) sensors operating in the Kretschmann configuration were investigated by numerical modeling and experiment. While Ag-based sensors have good sensitivity, they suffer from poor stability, and the addition of an Au capping layer offers improved chemical resistance and reliable analyte bonding via thiol–gold interactions. Sensors were evaluated with an Ag–Au combined thickness of 50 nm but different thickness ratios, and SPR reflectivity curves were obtained for 632.8 nm wavelength light incident over a range of angles. Numerical modeling using the transfer matrix method showed the SPR response improving as Au thickness decreased, giving the best results for 45 nm of Ag and 5 nm of Au. Experimental characterization of fabricated Ag–Au bimetallic sensors was carried out with a custom SPR testbed. Performance parameters, including minimum reflectivity, full-width at half-maximum (FWHM), stability, and sensitivity were measured and the results were compared to those of single-layer Ag and Au sensors. A 5 nm Au coating was unable to preserve stable bimetallic sensor performance; however, increasing the Au thickness to 10 nm was sufficient to protect the Ag sensing layer, allowing only a small variation in the minimum reflectivity and FWHM when exposed to analytes for multiple hours. The sensitivity of the single-layer Ag, bimetallic Ag–Au, and Au sensors was measured as 3041%/refractive index unit (RIU), 1817%/RIU, and 1229%/RIU, respectively. The sensitivity of the thickness-optimized bimetallic layer was ∼1.5× that of the single-layer Au sensor.

This record has no associated files available for download.

More information

Published date: 17 April 2023

Identifiers

Local EPrints ID: 505727
URI: http://eprints.soton.ac.uk/id/eprint/505727
ISSN: 1930-0395
PURE UUID: 38cc5aee-7823-4cce-b12b-16a908330348

Catalogue record

Date deposited: 16 Oct 2025 17:28
Last modified: 16 Oct 2025 17:28

Export record

Altmetrics

Contributors

Author: Roshni Babu
Author: Hamish Colenso
Author: Gideon Gouws
Author: Baptiste Auguié
Author: Ciaran Moore

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×