Overall and peripheral ratings of perceived exertion during a graded exercise test to volitional exhaustion in individuals of high and low fitness

Overall and peripheral ratings of perceived exertion during a graded exercise test to volitional exhaustion in individuals of high and low fitness
Overall and peripheral ratings of perceived exertion during a graded exercise test to volitional exhaustion in individuals of high and low fitness
This study assessed the relationship between differentiated ratings of perceived exertion (RPE) and heart rate with oxygen uptake (VO2) during two graded exercise tests (GXT) to exhaustion on a cycle ergometer in 49 men and women (19-50 years) of high and low fitness. The study also assessed whether sub-maximal RPE values elicited during the GXTs could provide appropriate estimates of maximal aerobic power (VO2max) Peripheral RPE (RPEP) was higher than overall RPE (RPEO) at exhaustion in both groups (P<0.001), but the reliability of the terminal RPEO was higher (0.75 and 0.40, respectively). Fitness did not moderate the relationship of RPEO and RPEP with VO2 during the GXTs (P>0.05). However, the correlation for RPEP and VO2 was higher for women compared to men (0.98 and 0.96, respectively, P<0.05), although this is of little practical significance. In both groups, RPEO was almost as highly correlated with VO2 as heart rate during GXTs terminated at exhaustion (approximately 0.955-0.980). There were no differences between predicted and measured VO2max when VO2 values were extrapolated from sub-maximal RPEO (13, 15 and 17) intensities (42.1+/-12.5, 43.4+/-11.5, 44.2+/-11.3 and 43.3+/-10.0 ml kg(-1) min(-1), respectively). However, VO2max predicted from sub-maximal RPEP intensities was significantly lower (P<0.05). In conclusion, terminal RPEO was a more reliable measure of the RPE, and provided more accurate estimates of VO2max in healthy participants of high and low fitness when elicited from sub-maximal exercise intensities.
1439-6319
613-620
Faulkner, James
b2bd38c9-667c-42e8-ad1e-6df58d1e3f7a
Eston, Roger
c2b0f27b-b9fc-4f6c-8429-4cfb7bb2a74a
Faulkner, James
b2bd38c9-667c-42e8-ad1e-6df58d1e3f7a
Eston, Roger
c2b0f27b-b9fc-4f6c-8429-4cfb7bb2a74a

Faulkner, James and Eston, Roger (2007) Overall and peripheral ratings of perceived exertion during a graded exercise test to volitional exhaustion in individuals of high and low fitness. European Journal of Applied Physiology, 101 (5), 613-620. (doi:10.1007/s00421-007-0536-2).

Record type: Article

Abstract

This study assessed the relationship between differentiated ratings of perceived exertion (RPE) and heart rate with oxygen uptake (VO2) during two graded exercise tests (GXT) to exhaustion on a cycle ergometer in 49 men and women (19-50 years) of high and low fitness. The study also assessed whether sub-maximal RPE values elicited during the GXTs could provide appropriate estimates of maximal aerobic power (VO2max) Peripheral RPE (RPEP) was higher than overall RPE (RPEO) at exhaustion in both groups (P<0.001), but the reliability of the terminal RPEO was higher (0.75 and 0.40, respectively). Fitness did not moderate the relationship of RPEO and RPEP with VO2 during the GXTs (P>0.05). However, the correlation for RPEP and VO2 was higher for women compared to men (0.98 and 0.96, respectively, P<0.05), although this is of little practical significance. In both groups, RPEO was almost as highly correlated with VO2 as heart rate during GXTs terminated at exhaustion (approximately 0.955-0.980). There were no differences between predicted and measured VO2max when VO2 values were extrapolated from sub-maximal RPEO (13, 15 and 17) intensities (42.1+/-12.5, 43.4+/-11.5, 44.2+/-11.3 and 43.3+/-10.0 ml kg(-1) min(-1), respectively). However, VO2max predicted from sub-maximal RPEP intensities was significantly lower (P<0.05). In conclusion, terminal RPEO was a more reliable measure of the RPE, and provided more accurate estimates of VO2max in healthy participants of high and low fitness when elicited from sub-maximal exercise intensities.

This record has no associated files available for download.

More information

Published date: 11 August 2007

Identifiers

Local EPrints ID: 506366
URI: http://eprints.soton.ac.uk/id/eprint/506366
ISSN: 1439-6319
PURE UUID: 2e1a7bd4-39d4-437d-8d29-a7933b3e8a2b
ORCID for James Faulkner: ORCID iD orcid.org/0000-0002-3704-6737

Catalogue record

Date deposited: 05 Nov 2025 17:37
Last modified: 06 Nov 2025 03:14

Export record

Altmetrics

Contributors

Author: James Faulkner ORCID iD
Author: Roger Eston

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×