A miniature ultrasonic surgical device based on a flextensional configuration with a pre-stressed piezoelectric stack

A miniature ultrasonic surgical device based on a flextensional configuration with a pre-stressed piezoelectric stack
A miniature ultrasonic surgical device based on a flextensional configuration with a pre-stressed piezoelectric stack
Ultrasonic bone scalpels are known to offer benefits of low cutting force, high precision, low microdamage around the cut site, and tissue selectivity in surgical procedures. However, all current commercial devices are too large to be integrated with the flexible endo-wrist of a surgical robot, and therefore, there is a significant gap for innovation in miniature devices. Ultrasonic bone scalpels in use in clinical settings are all based on a bolted Langevin transducer (BLT), which consists of a pre-stressed piezoceramic ring stack, two end masses, and a cutting blade. The BLT-based device must operate in resonance to achieve sufficient displacement amplitude at the surgical tip to cut through bone, and this dictates its size. Flextensional transducers have emerged as an alternative, but these transducers generally contain a low volume of piezoelectric driving material, and hence cannot excite the required displacement amplitude, and their reliance on adhesive bonds in their fabrication means they fail at the excitation levels required for a bone surgery device. We present a flextensional configuration that forms an ultrasonic surgical device, where the vibration-amplifying metal caps are excited by a pre-stressed piezoelectric stack. In vitro ultrasonic bone cutting tests facilitated with a Kuka robot are performed for a range of cutting speeds and penetration rates. The results demonstrate effective integration with a Kuka robot and that bone cutting can be achieved with an extremely low cutting force ( < 1 N) and high precision (the width of the bone cut presents under 6% deviation from the thickness of the blade). The flextensional device overcomes both the large size of conventional ultrasonic osteotomy devices and the displacement amplitude limitations of other miniaturisation approaches. Integration with an articulated robotic endo-wrist is enabled, establishing a foundation for low-force and high-precision ultrasonic bone cutting in minimally invasive, anatomically constrained robotic surgical environments.
2731-3395
Li, Xuan
ef7e6313-a655-4e1a-bdec-f8a024f80528
Jones, Dominic
892e39b8-e742-45a4-8fc5-5247a7b84d31
Valdastri, Pietro
ae518e2f-9e1e-472d-ae12-4f26abd1211e
Lucas, Margaret
2c2ddf40-32e0-41fd-a911-0a50f8d3d91f
Li, Xuan
ef7e6313-a655-4e1a-bdec-f8a024f80528
Jones, Dominic
892e39b8-e742-45a4-8fc5-5247a7b84d31
Valdastri, Pietro
ae518e2f-9e1e-472d-ae12-4f26abd1211e
Lucas, Margaret
2c2ddf40-32e0-41fd-a911-0a50f8d3d91f

Li, Xuan, Jones, Dominic, Valdastri, Pietro and Lucas, Margaret (2026) A miniature ultrasonic surgical device based on a flextensional configuration with a pre-stressed piezoelectric stack. Communications Engineering. (doi:10.1038/s44172-026-00651-2).

Record type: Article

Abstract

Ultrasonic bone scalpels are known to offer benefits of low cutting force, high precision, low microdamage around the cut site, and tissue selectivity in surgical procedures. However, all current commercial devices are too large to be integrated with the flexible endo-wrist of a surgical robot, and therefore, there is a significant gap for innovation in miniature devices. Ultrasonic bone scalpels in use in clinical settings are all based on a bolted Langevin transducer (BLT), which consists of a pre-stressed piezoceramic ring stack, two end masses, and a cutting blade. The BLT-based device must operate in resonance to achieve sufficient displacement amplitude at the surgical tip to cut through bone, and this dictates its size. Flextensional transducers have emerged as an alternative, but these transducers generally contain a low volume of piezoelectric driving material, and hence cannot excite the required displacement amplitude, and their reliance on adhesive bonds in their fabrication means they fail at the excitation levels required for a bone surgery device. We present a flextensional configuration that forms an ultrasonic surgical device, where the vibration-amplifying metal caps are excited by a pre-stressed piezoelectric stack. In vitro ultrasonic bone cutting tests facilitated with a Kuka robot are performed for a range of cutting speeds and penetration rates. The results demonstrate effective integration with a Kuka robot and that bone cutting can be achieved with an extremely low cutting force ( < 1 N) and high precision (the width of the bone cut presents under 6% deviation from the thickness of the blade). The flextensional device overcomes both the large size of conventional ultrasonic osteotomy devices and the displacement amplitude limitations of other miniaturisation approaches. Integration with an articulated robotic endo-wrist is enabled, establishing a foundation for low-force and high-precision ultrasonic bone cutting in minimally invasive, anatomically constrained robotic surgical environments.

Text
s44172-026-00651-2_reference - Version of Record
Available under License Creative Commons Attribution.
Download (2MB)

More information

Accepted/In Press date: 13 March 2026
e-pub ahead of print date: 26 March 2026

Identifiers

Local EPrints ID: 510566
URI: http://eprints.soton.ac.uk/id/eprint/510566
ISSN: 2731-3395
PURE UUID: 13e5232a-b1c5-485a-b143-9dc2aeed1ea1

Catalogue record

Date deposited: 13 Apr 2026 16:59
Last modified: 13 Apr 2026 21:18

Export record

Altmetrics

Contributors

Author: Xuan Li
Author: Dominic Jones
Author: Pietro Valdastri
Author: Margaret Lucas

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×