The University of Southampton
University of Southampton Institutional Repository

Risk identification in the early design stage using thermal simulations — a case study

Risk identification in the early design stage using thermal simulations — a case study
Risk identification in the early design stage using thermal simulations — a case study
The likely increasing temperature predicted by UK Climate Impacts Program (UKCIP) underlines the risk of overheating and potential increase in cooling loads in most of UK dwellings. This could also increase the possibility of failure in building performance evaluation methods and add even more uncertainty to the decision-making process in a low-carbon building design process. This paper uses a 55-unit residential unit project in Cardiff, UK as a case study to evaluate the potential of thermal simulations to identify risk in the early design stage. Overheating, increase in energy loads, carbon emissions, and thermal bridges are considered as potential risks in this study. DesignBuilder (DesignBuilder Software Ltd., Stroud, UK) was the dynamic thermal simulation software used in this research. Simulations compare results in the present, 2050, and 2080 time slices and quantifies the overall cooling and heating loads required to keep the operative temperature within the comfort zone. Overall carbon emissions are also calculated and a considerable reduction in the future is predicted. Further analysis was taken by THERM (Lawrence Berkeley National Laboratory, Berkeley, CA, USA) and Psi THERM (Passivate, London, UK) to evaluate the thermal bridge risk in most common junctions of the case study and the results reveal the potential of thermal assessment methods to improve design details before the start of construction stage.
2071-1050
Sajjadian, Seyed Masoud
f08f9a9d-5aee-4844-b4f9-b8f8fb454b5d
Sajjadian, Seyed Masoud
f08f9a9d-5aee-4844-b4f9-b8f8fb454b5d

Sajjadian, Seyed Masoud (2018) Risk identification in the early design stage using thermal simulations — a case study. Sustainability, 10 (1), [262]. (doi:10.3390/su10010262).

Record type: Article

Abstract

The likely increasing temperature predicted by UK Climate Impacts Program (UKCIP) underlines the risk of overheating and potential increase in cooling loads in most of UK dwellings. This could also increase the possibility of failure in building performance evaluation methods and add even more uncertainty to the decision-making process in a low-carbon building design process. This paper uses a 55-unit residential unit project in Cardiff, UK as a case study to evaluate the potential of thermal simulations to identify risk in the early design stage. Overheating, increase in energy loads, carbon emissions, and thermal bridges are considered as potential risks in this study. DesignBuilder (DesignBuilder Software Ltd., Stroud, UK) was the dynamic thermal simulation software used in this research. Simulations compare results in the present, 2050, and 2080 time slices and quantifies the overall cooling and heating loads required to keep the operative temperature within the comfort zone. Overall carbon emissions are also calculated and a considerable reduction in the future is predicted. Further analysis was taken by THERM (Lawrence Berkeley National Laboratory, Berkeley, CA, USA) and Psi THERM (Passivate, London, UK) to evaluate the thermal bridge risk in most common junctions of the case study and the results reveal the potential of thermal assessment methods to improve design details before the start of construction stage.

This record has no associated files available for download.

More information

Published date: 18 January 2018

Identifiers

Local EPrints ID: 511009
URI: http://eprints.soton.ac.uk/id/eprint/511009
ISSN: 2071-1050
PURE UUID: 0c4aef06-81c4-46f4-9e54-ec1a637d5482
ORCID for Seyed Masoud Sajjadian: ORCID iD orcid.org/0000-0001-5610-0498

Catalogue record

Date deposited: 28 Apr 2026 17:02
Last modified: 02 May 2026 02:22

Export record

Altmetrics

Contributors

Author: Seyed Masoud Sajjadian ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×