Carbon-optimised refurbishment measures for a simulated house in Edinburgh
Carbon-optimised refurbishment measures for a simulated house in Edinburgh
This research is conducted in the context of current efforts for net zero delivery in Scotland. Such a target is widely acknowledged as challenging by the industry necessitating some aspects of building design to change for higher performance. This study looks at ‘what is optimal’ in terms of carbon, both in operation and embodied in materials for dwellings by using the Pareto Optimal solution in a simulated case study in Edinburgh. At first, the potential of available glazing systems to find an optimum in operational and embodied carbon is investigated. The study then calculated the embodied carbon and operational carbon for added insulation and compared them against each other to find the most energy and environmentally-efficient option. An analysis to investigate the LCA of the 52 HVAC systems for the second phase of the building's life span is then conducted and finally a parametric analysis of using shading devices to observe if they can offer operational savings for the case study concludes the paper. This study demonstrates some recommended design solutions by globally used standards e.g. Passivhaus and common practices may not lead to carbon emissions minimisation in the refurbishment process.
105-114
Sajjadian, Seyed Masoud
f08f9a9d-5aee-4844-b4f9-b8f8fb454b5d
2025
Sajjadian, Seyed Masoud
f08f9a9d-5aee-4844-b4f9-b8f8fb454b5d
Sajjadian, Seyed Masoud
(2025)
Carbon-optimised refurbishment measures for a simulated house in Edinburgh.
Intelligent Buildings International, 17 (3), .
(doi:10.1080/17508975.2025.2480114).
Abstract
This research is conducted in the context of current efforts for net zero delivery in Scotland. Such a target is widely acknowledged as challenging by the industry necessitating some aspects of building design to change for higher performance. This study looks at ‘what is optimal’ in terms of carbon, both in operation and embodied in materials for dwellings by using the Pareto Optimal solution in a simulated case study in Edinburgh. At first, the potential of available glazing systems to find an optimum in operational and embodied carbon is investigated. The study then calculated the embodied carbon and operational carbon for added insulation and compared them against each other to find the most energy and environmentally-efficient option. An analysis to investigate the LCA of the 52 HVAC systems for the second phase of the building's life span is then conducted and finally a parametric analysis of using shading devices to observe if they can offer operational savings for the case study concludes the paper. This study demonstrates some recommended design solutions by globally used standards e.g. Passivhaus and common practices may not lead to carbon emissions minimisation in the refurbishment process.
Text
Carbon-optimised refurbishment measures for a simulated house in Edinburgh
- Version of Record
More information
Accepted/In Press date: 7 March 2025
e-pub ahead of print date: 20 March 2025
Published date: 2025
Identifiers
Local EPrints ID: 512128
URI: http://eprints.soton.ac.uk/id/eprint/512128
ISSN: 1750-8975
PURE UUID: 43f90e38-7516-4cd8-924f-60fea2132a2a
Catalogue record
Date deposited: 17 Jun 2026 16:32
Last modified: 20 Aug 2026 03:03
Export record
Altmetrics
Contributors
Author:
Seyed Masoud Sajjadian
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics