Evaluation of a laboratory-scale stabilization pond for tertiary treatment of distillery waste previously treated by a combined anaerobic filter–aerobic trickling system

Evaluation of a laboratory-scale stabilization pond for tertiary treatment of distillery waste previously treated by a combined anaerobic filter–aerobic trickling system
Evaluation of a laboratory-scale stabilization pond for tertiary treatment of distillery waste previously treated by a combined anaerobic filter–aerobic trickling system
Distillery waste tertiary treatment in a laboratory stabilization pond was evaluated. Effluents from a combined laboratory-scale anaerobic filter–aerobic trickling filter process were used as the influent. The effect of the hydraulic retention time (HRT) in the range of 5–30 days was evaluated at influent total chemical oxygen demand (TCOD) in the range of 271–5286 mg/l (BOD5 in the range of 66–1212 mg/l). TCOD and BOD5 removals of up to 54% and 74%, respectively, were obtained for the most concentrated influent used at 30 days of HRT. The effect of the HRT on TCOD and BOD5 removal efficiencies followed an exponential relationship. An empirical equation adequately described the effect of the organic surface-loading rate on the process efficiency. The pond acted as an intermediate flow pattern between completely mixed flow and plug-flow. It was found that a second-order model fit in well with the experimental results of organic matter removal rate and effluent substrate concentration. The second-order kinetic constant was found to be Ks = 0.23 mg BOD5/mg TSS day. The proposed model accurately predicted the behaviour of the pond showing deviations between the experimental and theoretical values of effluent substrate concentrations equal to or lower than 11%.
stabilization pond, distillery waste, tertiary treatment, kinetics, operational parameters
0925-8574
100-108
Travieso, L.
e85f590a-0cde-40ad-9048-6b8dba325367
Sánchez, E.
cf73c967-6a9b-4a5e-8e99-26198ecc3d6c
Borja, R.
ed513484-04ff-4424-ab79-dc715ca63146
Benítez, F.
1a4903c0-9b2a-4c23-b0a2-4bba963129cd
Raposo, F.
47104451-511a-4b03-aaa9-67348da4567d
Rincón, B.
d8fe6652-8ff6-4662-bfb7-3b231d140957
Jiménez, A.M.
19955253-d18a-4dfd-8c61-dd1980b150eb
Travieso, L.
e85f590a-0cde-40ad-9048-6b8dba325367
Sánchez, E.
cf73c967-6a9b-4a5e-8e99-26198ecc3d6c
Borja, R.
ed513484-04ff-4424-ab79-dc715ca63146
Benítez, F.
1a4903c0-9b2a-4c23-b0a2-4bba963129cd
Raposo, F.
47104451-511a-4b03-aaa9-67348da4567d
Rincón, B.
d8fe6652-8ff6-4662-bfb7-3b231d140957
Jiménez, A.M.
19955253-d18a-4dfd-8c61-dd1980b150eb

Travieso, L., Sánchez, E., Borja, R., Benítez, F., Raposo, F., Rincón, B. and Jiménez, A.M. (2006) Evaluation of a laboratory-scale stabilization pond for tertiary treatment of distillery waste previously treated by a combined anaerobic filter–aerobic trickling system. Ecological Engineering, 27 (2), 100-108. (doi:10.1016/j.ecoleng.2005.11.004).

Record type: Article

Abstract

Distillery waste tertiary treatment in a laboratory stabilization pond was evaluated. Effluents from a combined laboratory-scale anaerobic filter–aerobic trickling filter process were used as the influent. The effect of the hydraulic retention time (HRT) in the range of 5–30 days was evaluated at influent total chemical oxygen demand (TCOD) in the range of 271–5286 mg/l (BOD5 in the range of 66–1212 mg/l). TCOD and BOD5 removals of up to 54% and 74%, respectively, were obtained for the most concentrated influent used at 30 days of HRT. The effect of the HRT on TCOD and BOD5 removal efficiencies followed an exponential relationship. An empirical equation adequately described the effect of the organic surface-loading rate on the process efficiency. The pond acted as an intermediate flow pattern between completely mixed flow and plug-flow. It was found that a second-order model fit in well with the experimental results of organic matter removal rate and effluent substrate concentration. The second-order kinetic constant was found to be Ks = 0.23 mg BOD5/mg TSS day. The proposed model accurately predicted the behaviour of the pond showing deviations between the experimental and theoretical values of effluent substrate concentrations equal to or lower than 11%.

This record has no associated files available for download.

More information

Submitted date: 13 October 2005
Published date: 28 September 2006
Additional Information: Travieso L, Sanchez E, Borja R, Benitez F, Raposo F, Rincon B., Jiminez AM, (2006). "Evaluation of a laboratory-scale stabilization pond for tertiary treatment of distillery waste previously treated by a combined anaerobic filter-aerobic trickling system." Ecological Engineering, 27(2), 100-108
Keywords: stabilization pond, distillery waste, tertiary treatment, kinetics, operational parameters

Identifiers

Local EPrints ID: 53021
URI: http://eprints.soton.ac.uk/id/eprint/53021
ISSN: 0925-8574
PURE UUID: bcf39994-82e6-4097-9f6c-2864379564f5

Catalogue record

Date deposited: 22 Jul 2008
Last modified: 11 Nov 2024 19:38

Export record

Altmetrics

Contributors

Author: L. Travieso
Author: E. Sánchez
Author: R. Borja
Author: F. Benítez
Author: F. Raposo
Author: B. Rincón
Author: A.M. Jiménez

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×