Simulated electrical power potential harnessed by marine current turbine arrays in the Alderney Race
Simulated electrical power potential harnessed by marine current turbine arrays in the Alderney Race
Utilising marine currents for electricity generation could offer a distinct advantage over other renewable energy sources due to the regular and predictable nature of the resource. This paper details the design of a horizontal axis Marine Current Turbine using 2D aerofoil data and a blade element momentum software package. Tidal current data from the Race of Alderney situated in the Channel Islands is used to run simulations of the turbine over various flow regimes and yield the energy capture with time. The results of the simulations are combined with an analytical method that details the layout and energy capture potential throughout a large-scale array. Several array configurations, sizes, and the impact of spacings (between rows and turbines) on the velocity distribution were considered in the analysis. The optimum configuration predicted an annual energy output of 1340 GW h at a rated array capacity of approximately 1.5 GW.
1713-1731
Myers, L.
b0462700-3740-4f03-a336-dc5dd1969228
Bahaj, A. S.
a64074cc-2b6e-43df-adac-a8437e7f1b37
September 2005
Myers, L.
b0462700-3740-4f03-a336-dc5dd1969228
Bahaj, A. S.
a64074cc-2b6e-43df-adac-a8437e7f1b37
Myers, L. and Bahaj, A. S.
(2005)
Simulated electrical power potential harnessed by marine current turbine arrays in the Alderney Race.
Renewable Energy, 30 (11), .
(doi:10.1016/j.renene.2005.02.008).
Abstract
Utilising marine currents for electricity generation could offer a distinct advantage over other renewable energy sources due to the regular and predictable nature of the resource. This paper details the design of a horizontal axis Marine Current Turbine using 2D aerofoil data and a blade element momentum software package. Tidal current data from the Race of Alderney situated in the Channel Islands is used to run simulations of the turbine over various flow regimes and yield the energy capture with time. The results of the simulations are combined with an analytical method that details the layout and energy capture potential throughout a large-scale array. Several array configurations, sizes, and the impact of spacings (between rows and turbines) on the velocity distribution were considered in the analysis. The optimum configuration predicted an annual energy output of 1340 GW h at a rated array capacity of approximately 1.5 GW.
This record has no associated files available for download.
More information
Published date: September 2005
Identifiers
Local EPrints ID: 53792
URI: http://eprints.soton.ac.uk/id/eprint/53792
ISSN: 0960-1481
PURE UUID: 463b7b28-9a37-4265-a87c-6edb5316b204
Catalogue record
Date deposited: 16 Jul 2008
Last modified: 16 Mar 2024 03:24
Export record
Altmetrics
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics