The University of Southampton
University of Southampton Institutional Repository

Pseudoparalysis in the Pavlik Harness: beware septic arthritis

Pseudoparalysis in the Pavlik Harness: beware septic arthritis
Pseudoparalysis in the Pavlik Harness: beware septic arthritis
Purpose Pseudoparalysis of the leg occurring during use of the Pavlik Harness (PH) is a seldom-reported condition. Three cases of pseudoparalysis are reported here to illustrate the need for careful assessment of this condition. Methods A series of patients using the PH and presenting with pseudoparalysis was compiled following a retrospective review of case notes. Results In 3 cases, infants treated for developmental dysplasia of the hip using the PH were found to have developed a pseudoparalysis of the affected limb. All presented with similar signs, with the infant being systemically irritable and reluctant to move the limb. In 2 of the cases, this was related to the harness—its removal resulted in recovery of the affected limb. The third case was proven to be septic arthritis, unrelated to the harness, and treatment by means of arthrotomy, intravenous antibiotics and use of the PH for hip stabilisation was used successfully. In the first two cases, the pseudoparalysis was noticed at routine review clinic, and clinical assessment, ultrasound scan and blood tests were performed. The case of septic arthritis was similarly assessed, following referral by paediatric physicians. Conclusion Pseudoparalysis in the PH is a rare event and requires careful investigation.
Pavlik harness, Pseudoparalysis, Septic arthritis
1863-2521
287-289
Stevenson, A.J.
9fc68779-ecb3-4f76-8795-7541eb76b8a7
Shelwalle, S.B.
21286fb8-a128-463d-b4d7-5bde0522514f
Clarke, N.M.P.
76688c21-d51e-48fa-a84d-deec66baf8ac
Stevenson, A.J.
9fc68779-ecb3-4f76-8795-7541eb76b8a7
Shelwalle, S.B.
21286fb8-a128-463d-b4d7-5bde0522514f
Clarke, N.M.P.
76688c21-d51e-48fa-a84d-deec66baf8ac

Stevenson, A.J., Shelwalle, S.B. and Clarke, N.M.P. (2007) Pseudoparalysis in the Pavlik Harness: beware septic arthritis. Journal of Children's Orthopaedics, 1 (5), 287-289. (doi:10.1007/s11832-007-0052-2).

Record type: Article

Abstract

Purpose Pseudoparalysis of the leg occurring during use of the Pavlik Harness (PH) is a seldom-reported condition. Three cases of pseudoparalysis are reported here to illustrate the need for careful assessment of this condition. Methods A series of patients using the PH and presenting with pseudoparalysis was compiled following a retrospective review of case notes. Results In 3 cases, infants treated for developmental dysplasia of the hip using the PH were found to have developed a pseudoparalysis of the affected limb. All presented with similar signs, with the infant being systemically irritable and reluctant to move the limb. In 2 of the cases, this was related to the harness—its removal resulted in recovery of the affected limb. The third case was proven to be septic arthritis, unrelated to the harness, and treatment by means of arthrotomy, intravenous antibiotics and use of the PH for hip stabilisation was used successfully. In the first two cases, the pseudoparalysis was noticed at routine review clinic, and clinical assessment, ultrasound scan and blood tests were performed. The case of septic arthritis was similarly assessed, following referral by paediatric physicians. Conclusion Pseudoparalysis in the PH is a rare event and requires careful investigation.

This record has no associated files available for download.

More information

Published date: 2007
Keywords: Pavlik harness, Pseudoparalysis, Septic arthritis

Identifiers

Local EPrints ID: 61539
URI: http://eprints.soton.ac.uk/id/eprint/61539
ISSN: 1863-2521
PURE UUID: 9b569bb7-6ce1-425c-81ef-02cfe35c056b

Catalogue record

Date deposited: 12 Sep 2008
Last modified: 15 Mar 2024 11:27

Export record

Altmetrics

Contributors

Author: A.J. Stevenson
Author: S.B. Shelwalle
Author: N.M.P. Clarke

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×