Effects of maturation on parameters used for pass/fail criteria in neonatal hearing screening programmes using evoked otoacoustic emissions
Effects of maturation on parameters used for pass/fail criteria in neonatal hearing screening programmes using evoked otoacoustic emissions
We aimed to investigate the incidence of false alarms that occurred with the pass/fail criteria used in a published series of neonatal hearing screening programmes, as a function of age. We analysed the database of 19137 normally hearing babies (38274 ears) tested in the Wessex Universal Neonatal Hearing Screening Project. Otoacoustic emissions were recorded prior to discharge from maternity units, using IL088 equipment. We assessed the pass/fail rate using the Wessex criteria and 10 other pass/fail criteria published in the literature. Using Pearson's correlation coefficient, a statistically significant correlation between signal-to-noise ratio at each of the frequency bands 1, 2, 3, 4 and 5 kHz and babies' age in hours at the 0.01 level was identified. The correlation was also significant (0.01 level) between age and frequency reproducibility in each of the bands at 1, 2, 3, 4 and 5 kHz as well as the whole reproducibility. The number of false alarms reduced significantly after the first 24 h of life with all the criteria examined. We conclude that in the first hours after birth due to insufficient maturation of the otoacoustic emission, there is a high rate of false alarms. This increase in the false alarm rate, whilst dependent on the criteria used, occurs with all criteria. This leads to the consideration of whether the establishment of age-dependent pass/fail criteria could reduce the false alarm rate and the subsequent strain on diagnostic centres. Copyright (c) 2007 S. Karger AG, Basel
newborn hearing screening, ear, impairment, transient evoked otoacoustic emissions, neonatal hearing screening, newborns, brain-stem response, identification, number, project, pass-fail criteria
226-233
Sadri, M.
1d4d2d1e-c989-4ee0-a285-26d55947be65
Thornton, A.R.D.
c521ce20-d056-4748-af28-e2293f3593d0
Kennedy, C.R.
7c3aff62-0a86-4b44-b7d7-4bc01f23ec93
2007
Sadri, M.
1d4d2d1e-c989-4ee0-a285-26d55947be65
Thornton, A.R.D.
c521ce20-d056-4748-af28-e2293f3593d0
Kennedy, C.R.
7c3aff62-0a86-4b44-b7d7-4bc01f23ec93
Sadri, M., Thornton, A.R.D. and Kennedy, C.R.
(2007)
Effects of maturation on parameters used for pass/fail criteria in neonatal hearing screening programmes using evoked otoacoustic emissions.
Audiology and Neuro-Otology, 12 (4), .
(doi:10.1159/000101330).
Abstract
We aimed to investigate the incidence of false alarms that occurred with the pass/fail criteria used in a published series of neonatal hearing screening programmes, as a function of age. We analysed the database of 19137 normally hearing babies (38274 ears) tested in the Wessex Universal Neonatal Hearing Screening Project. Otoacoustic emissions were recorded prior to discharge from maternity units, using IL088 equipment. We assessed the pass/fail rate using the Wessex criteria and 10 other pass/fail criteria published in the literature. Using Pearson's correlation coefficient, a statistically significant correlation between signal-to-noise ratio at each of the frequency bands 1, 2, 3, 4 and 5 kHz and babies' age in hours at the 0.01 level was identified. The correlation was also significant (0.01 level) between age and frequency reproducibility in each of the bands at 1, 2, 3, 4 and 5 kHz as well as the whole reproducibility. The number of false alarms reduced significantly after the first 24 h of life with all the criteria examined. We conclude that in the first hours after birth due to insufficient maturation of the otoacoustic emission, there is a high rate of false alarms. This increase in the false alarm rate, whilst dependent on the criteria used, occurs with all criteria. This leads to the consideration of whether the establishment of age-dependent pass/fail criteria could reduce the false alarm rate and the subsequent strain on diagnostic centres. Copyright (c) 2007 S. Karger AG, Basel
This record has no associated files available for download.
More information
Published date: 2007
Keywords:
newborn hearing screening, ear, impairment, transient evoked otoacoustic emissions, neonatal hearing screening, newborns, brain-stem response, identification, number, project, pass-fail criteria
Identifiers
Local EPrints ID: 62561
URI: http://eprints.soton.ac.uk/id/eprint/62561
ISSN: 1420-3030
PURE UUID: 8e16c3d7-b680-4f27-a33b-5b61ac2048ea
Catalogue record
Date deposited: 04 Sep 2008
Last modified: 15 Mar 2024 11:31
Export record
Altmetrics
Contributors
Author:
M. Sadri
Author:
A.R.D. Thornton
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics