Two-phase flow characterization by automated digital image analysis. part 1: fundamental principles and calibration of the technique
Two-phase flow characterization by automated digital image analysis. part 1: fundamental principles and calibration of the technique
A recently developed digital image analysis technique potentially capable of sizing particles of arbitrary shape and size and with wide dynamic range is examined. Shadow images of droplets or particles are produced in this case by back-illumination using an infra-red diode laser. The measurement performance of the particle/droplet image analysis (PDIA) system has been assessed initially in terms of individual object diameters and the aim of this experimental investigation was to assess the robustness and accuracy of the technique. The first part of this paper provides a description of the fundamental principles of the technique followed by a thorough description of the calibration procedure in which the image processing routine was verified with calibration data of known particle sizes. The lens-camera optical behavior has been characterized whilst the relative uncertainties of various parameters such as the depth-of-field dependence on particle diameter, threshold level sensitivity and image signal-to-noise issues have been quantified and their effects on measurement accuracy discussed. Calibration data revealed that the depth-of-field varied with object diameter approximately linearly in the measured range 18 to 145 m. The calibration data is subsequently incorporated into the PDIA processing algorithm and for defocused droplets or particles, enables their true diameter to be estimated by analyzing the droplet image properties. Greater emphasis on the application of the PDIA technique is deferred to the second part of this two-part paper where droplet size data obtained from a hollow-cone spray is compared with similar data measured via phase Doppler anemometry (PDA).
depth-of-field, droplet sizing, digital image analysis, two-phase flows
387-397
Shrimpton, J.S.
9cf82d2e-2f00-4ddf-bd19-9aff443784af
Kashdan, J.T.
7154b9cb-cc19-46b3-8610-98ef0ac88123
Whybrew, A.
14f51e11-a1c2-4a39-82a9-f372f4db0e7b
9 February 2004
Shrimpton, J.S.
9cf82d2e-2f00-4ddf-bd19-9aff443784af
Kashdan, J.T.
7154b9cb-cc19-46b3-8610-98ef0ac88123
Whybrew, A.
14f51e11-a1c2-4a39-82a9-f372f4db0e7b
Shrimpton, J.S., Kashdan, J.T. and Whybrew, A.
(2004)
Two-phase flow characterization by automated digital image analysis. part 1: fundamental principles and calibration of the technique.
Particle & Particle Systems Characterization, 20 (6), .
(doi:10.1002/ppsc.200300897).
Abstract
A recently developed digital image analysis technique potentially capable of sizing particles of arbitrary shape and size and with wide dynamic range is examined. Shadow images of droplets or particles are produced in this case by back-illumination using an infra-red diode laser. The measurement performance of the particle/droplet image analysis (PDIA) system has been assessed initially in terms of individual object diameters and the aim of this experimental investigation was to assess the robustness and accuracy of the technique. The first part of this paper provides a description of the fundamental principles of the technique followed by a thorough description of the calibration procedure in which the image processing routine was verified with calibration data of known particle sizes. The lens-camera optical behavior has been characterized whilst the relative uncertainties of various parameters such as the depth-of-field dependence on particle diameter, threshold level sensitivity and image signal-to-noise issues have been quantified and their effects on measurement accuracy discussed. Calibration data revealed that the depth-of-field varied with object diameter approximately linearly in the measured range 18 to 145 m. The calibration data is subsequently incorporated into the PDIA processing algorithm and for defocused droplets or particles, enables their true diameter to be estimated by analyzing the droplet image properties. Greater emphasis on the application of the PDIA technique is deferred to the second part of this two-part paper where droplet size data obtained from a hollow-cone spray is compared with similar data measured via phase Doppler anemometry (PDA).
This record has no associated files available for download.
More information
Published date: 9 February 2004
Keywords:
depth-of-field, droplet sizing, digital image analysis, two-phase flows
Identifiers
Local EPrints ID: 64551
URI: http://eprints.soton.ac.uk/id/eprint/64551
ISSN: 0934-0866
PURE UUID: 37a8660f-c8ae-4a0e-855c-7ee74c701c00
Catalogue record
Date deposited: 23 Dec 2008
Last modified: 15 Mar 2024 11:50
Export record
Altmetrics
Contributors
Author:
J.T. Kashdan
Author:
A. Whybrew
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics