The University of Southampton
University of Southampton Institutional Repository

An analytical technique to recover the third dimension in planar imaging of inhaled aerosols--2 estimation of the deposition per airway generation

An analytical technique to recover the third dimension in planar imaging of inhaled aerosols--2 estimation of the deposition per airway generation
An analytical technique to recover the third dimension in planar imaging of inhaled aerosols--2 estimation of the deposition per airway generation
An analytical algorithm has been recently described for converting planar scintigraphic images of aerosol distributions in the lungs to an equivalent three-dimensional (3D) representation. The recovery of the volumetric information has opened up to planar imaging the possibility of measuring aerosol deposition per airway generation. This paper investigates the accuracy and precision of the generation analysis achievable with planar imaging using simulation. Typical generation parameters—such as the bronchial and conducting airway deposition fractions (BADF and CADF)—have been derived. The accuracy of the technique has been measured by the coefficient of variation (COV) of the estimates from the known values used in the simulation. The results have also been compared to those obtained from 3D imaging (single photon emission computed tomography or SPECT). Finally, the technique has been applied to two aerosol studies conducted on a healthy volunteer, to demonstrate its implementation on clinical data. The accuracy of the BADF and CADF estimates from planar imaging were 42% and 41%, respectively; the corresponding values from SPECT were 32% and 22%. In conclusion, approximate estimates of airway distribution parameters can be derived from planar imaging. However, the errors are significantly higher than with SPECT.
127-140
Tossici-Bolt, Livia
a9bd79ee-18c7-40c0-a1a8-2d826e4be759
Fleming, John S.
9a23102d-6740-430a-ac74-89938b328ec3
Conway, Joy H.
bbe9a2e4-fb85-4d4a-a38c-0c1832c32d06
Martonen, Theodore B.
cc4da97c-e74f-4c72-aa89-5461968f91fe
Tossici-Bolt, Livia
a9bd79ee-18c7-40c0-a1a8-2d826e4be759
Fleming, John S.
9a23102d-6740-430a-ac74-89938b328ec3
Conway, Joy H.
bbe9a2e4-fb85-4d4a-a38c-0c1832c32d06
Martonen, Theodore B.
cc4da97c-e74f-4c72-aa89-5461968f91fe

Tossici-Bolt, Livia, Fleming, John S., Conway, Joy H. and Martonen, Theodore B. (2007) An analytical technique to recover the third dimension in planar imaging of inhaled aerosols--2 estimation of the deposition per airway generation. Journal of Aerosol Medicine, 20 (2), 127-140. (doi:10.1089/jam.2007.0577).

Record type: Article

Abstract

An analytical algorithm has been recently described for converting planar scintigraphic images of aerosol distributions in the lungs to an equivalent three-dimensional (3D) representation. The recovery of the volumetric information has opened up to planar imaging the possibility of measuring aerosol deposition per airway generation. This paper investigates the accuracy and precision of the generation analysis achievable with planar imaging using simulation. Typical generation parameters—such as the bronchial and conducting airway deposition fractions (BADF and CADF)—have been derived. The accuracy of the technique has been measured by the coefficient of variation (COV) of the estimates from the known values used in the simulation. The results have also been compared to those obtained from 3D imaging (single photon emission computed tomography or SPECT). Finally, the technique has been applied to two aerosol studies conducted on a healthy volunteer, to demonstrate its implementation on clinical data. The accuracy of the BADF and CADF estimates from planar imaging were 42% and 41%, respectively; the corresponding values from SPECT were 32% and 22%. In conclusion, approximate estimates of airway distribution parameters can be derived from planar imaging. However, the errors are significantly higher than with SPECT.

This record has no associated files available for download.

More information

Published date: 2007

Identifiers

Local EPrints ID: 72480
URI: http://eprints.soton.ac.uk/id/eprint/72480
PURE UUID: d6c09014-8ec0-400b-8a53-6e022ccbf183
ORCID for Joy H. Conway: ORCID iD orcid.org/0000-0001-6464-1526

Catalogue record

Date deposited: 16 Feb 2010
Last modified: 13 Mar 2024 21:31

Export record

Altmetrics

Contributors

Author: Livia Tossici-Bolt
Author: John S. Fleming
Author: Joy H. Conway ORCID iD
Author: Theodore B. Martonen

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×