Waveguide immunofluorescence sensor for water pollution analysis
Waveguide immunofluorescence sensor for water pollution analysis
A regenerable channel waveguide fluorescence sensor for environmental monitoring is reported. The sensor has been characterised as a detector of the pesticide 2,4 dichlorophenoxyacetic acid. A binding inhibition assay, using fluorescent Cy5.5 dye-labelled antibodies, was monitored at the modified surface of the glass waveguide to detect the target analyte. Three calibration curves were determined and averaged. The averaged calibration curve has a mid-point of 0.68 ppb and a calculated detection limit of 0.28 ppb. Incorporation of a 20 nm thick tantalum pentoxide film at the waveguide surface enhanced the peak fluorescence signal by a factor of approximately 6 compared with an uncoated sensor. Due to the high optical field strengths at the surface of the waveguide, which is approximately 10µm wide, significant photobleaching of the dye molecules occurs. The rate of photobleaching will be reduced if the power density of the excitation radiation at the surface of the waveguide is reduced, offering the potential for enhanced device sensitivity. This may be achieved, without reducing the total power, by broadening the 10µm wide optical waveguide through a tapered region to a final width in excess of 50µm. A distinct advantage of this broadening is to improve the signal to noise ratio of the sensor as the number of bound fluorophores at the waveguide surface increases linearly with the waveguide width. Theoretical modelling of tapered waveguides, using a beam propagation method package, has indicated that the peak field intensity of radiation in the 10µm guide may be reduced by 85% if the guide is broadened through a taper to a final width of 50µm.
Harris, R.D.
e972b676-3335-44cd-b6e8-0dae17c550c3
Quigley, G.R.
7d719dee-8822-4f48-9a29-52c7bc000a27
Wilkinson, J.S.
73483cf3-d9f2-4688-9b09-1c84257884ca
Klotz, A.
6295d51a-2cbd-4ebd-ac4f-de919e314636
Barzen, C.
e57de777-3451-4b75-b44a-937e8a317e5b
Brecht, A.
1b34ee2a-ada5-48ec-923a-f385835fbc83
Gauglitz, G.
119b102d-52db-4eba-81c0-0bdd5a16f1e7
Abuknesha, R.A.
f8222e58-66df-41c8-912f-1a11b2c3db6d
Harris, R.D.
e972b676-3335-44cd-b6e8-0dae17c550c3
Quigley, G.R.
7d719dee-8822-4f48-9a29-52c7bc000a27
Wilkinson, J.S.
73483cf3-d9f2-4688-9b09-1c84257884ca
Klotz, A.
6295d51a-2cbd-4ebd-ac4f-de919e314636
Barzen, C.
e57de777-3451-4b75-b44a-937e8a317e5b
Brecht, A.
1b34ee2a-ada5-48ec-923a-f385835fbc83
Gauglitz, G.
119b102d-52db-4eba-81c0-0bdd5a16f1e7
Abuknesha, R.A.
f8222e58-66df-41c8-912f-1a11b2c3db6d
Harris, R.D., Quigley, G.R., Wilkinson, J.S., Klotz, A., Barzen, C., Brecht, A., Gauglitz, G. and Abuknesha, R.A.
(1998)
Waveguide immunofluorescence sensor for water pollution analysis.
SPIE International Symposium on Industrial & Environmental Monitors & Biosensors, Boston, United States.
01 - 06 Nov 1998.
Record type:
Conference or Workshop Item
(Paper)
Abstract
A regenerable channel waveguide fluorescence sensor for environmental monitoring is reported. The sensor has been characterised as a detector of the pesticide 2,4 dichlorophenoxyacetic acid. A binding inhibition assay, using fluorescent Cy5.5 dye-labelled antibodies, was monitored at the modified surface of the glass waveguide to detect the target analyte. Three calibration curves were determined and averaged. The averaged calibration curve has a mid-point of 0.68 ppb and a calculated detection limit of 0.28 ppb. Incorporation of a 20 nm thick tantalum pentoxide film at the waveguide surface enhanced the peak fluorescence signal by a factor of approximately 6 compared with an uncoated sensor. Due to the high optical field strengths at the surface of the waveguide, which is approximately 10µm wide, significant photobleaching of the dye molecules occurs. The rate of photobleaching will be reduced if the power density of the excitation radiation at the surface of the waveguide is reduced, offering the potential for enhanced device sensitivity. This may be achieved, without reducing the total power, by broadening the 10µm wide optical waveguide through a tapered region to a final width in excess of 50µm. A distinct advantage of this broadening is to improve the signal to noise ratio of the sensor as the number of bound fluorophores at the waveguide surface increases linearly with the waveguide width. Theoretical modelling of tapered waveguides, using a beam propagation method package, has indicated that the peak field intensity of radiation in the 10µm guide may be reduced by 85% if the guide is broadened through a taper to a final width of 50µm.
Text
1711
- Author's Original
More information
e-pub ahead of print date: 1998
Venue - Dates:
SPIE International Symposium on Industrial & Environmental Monitors & Biosensors, Boston, United States, 1998-11-01 - 1998-11-06
Identifiers
Local EPrints ID: 76616
URI: http://eprints.soton.ac.uk/id/eprint/76616
PURE UUID: af2a1c31-cee0-40e7-a7bb-adc0fa5b2724
Catalogue record
Date deposited: 11 Mar 2010
Last modified: 14 Mar 2024 02:32
Export record
Contributors
Author:
R.D. Harris
Author:
G.R. Quigley
Author:
A. Klotz
Author:
C. Barzen
Author:
A. Brecht
Author:
G. Gauglitz
Author:
R.A. Abuknesha
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics