Southampton underwater multiparameter optical-fibre spectrometer system (SUMOSS)
Southampton underwater multiparameter optical-fibre spectrometer system (SUMOSS)
The SUMOSS was designed to measure simultaneously a number of inherent and apparent optical properties at high spectral resolution (<5 nm). The sensors consist of a transmissometer to measure beam attenuation, plane irradiance sensors (to measure reflectance, K-d and K-u) and a scalar irradiance sensor for calculating the absorption coefficient. The SUMOSS was designed to minimize the effects of self-shading of the sensors. The radiometric stability of the instrument across the visible spectrum (350-720 nm) was assessed in a series of dark room experiments. The linearity of the response of the passive sensors was evaluated over a range of intensities and was found to be stable to within 1%. The spectral resolution was measured using red and green lasers on the passive channels (FWHM 4 nm, sampling interval 0.4 nm). Radiometric calibrations showed that there was minimal variability in the spectral response over time. The SUMOSS has been deployed in three optically different water masses (the Baltic, Mediterranean and UK) and the spectral quality and intensity of the readings is interpreted using measurements of the concentrations of suspended particulate material and chlorophyll.
1168-1177
Weeks, A.R.
03ffbc83-d585-43eb-9bdf-cd279656a020
Robinson, I.S.
34a96496-b35d-40fa-b649-946105930512
Schwarz, J.N.
d7720f0c-84da-4942-9c2c-b5112eccb88b
Trundle, K.J.
8aea015e-9e61-44c1-979b-dae574bc1a07
1999
Weeks, A.R.
03ffbc83-d585-43eb-9bdf-cd279656a020
Robinson, I.S.
34a96496-b35d-40fa-b649-946105930512
Schwarz, J.N.
d7720f0c-84da-4942-9c2c-b5112eccb88b
Trundle, K.J.
8aea015e-9e61-44c1-979b-dae574bc1a07
Weeks, A.R., Robinson, I.S., Schwarz, J.N. and Trundle, K.J.
(1999)
Southampton underwater multiparameter optical-fibre spectrometer system (SUMOSS).
Measurement Science and Technology, 10 (12), .
(doi:10.1088/0957-0233/10/12/308).
Abstract
The SUMOSS was designed to measure simultaneously a number of inherent and apparent optical properties at high spectral resolution (<5 nm). The sensors consist of a transmissometer to measure beam attenuation, plane irradiance sensors (to measure reflectance, K-d and K-u) and a scalar irradiance sensor for calculating the absorption coefficient. The SUMOSS was designed to minimize the effects of self-shading of the sensors. The radiometric stability of the instrument across the visible spectrum (350-720 nm) was assessed in a series of dark room experiments. The linearity of the response of the passive sensors was evaluated over a range of intensities and was found to be stable to within 1%. The spectral resolution was measured using red and green lasers on the passive channels (FWHM 4 nm, sampling interval 0.4 nm). Radiometric calibrations showed that there was minimal variability in the spectral response over time. The SUMOSS has been deployed in three optically different water masses (the Baltic, Mediterranean and UK) and the spectral quality and intensity of the readings is interpreted using measurements of the concentrations of suspended particulate material and chlorophyll.
This record has no associated files available for download.
More information
Published date: 1999
Identifiers
Local EPrints ID: 77739
URI: http://eprints.soton.ac.uk/id/eprint/77739
ISSN: 0957-0233
PURE UUID: f670897c-b65c-4416-a0c4-2fb10fbf0db5
Catalogue record
Date deposited: 11 Mar 2010
Last modified: 13 Mar 2024 23:59
Export record
Altmetrics
Contributors
Author:
A.R. Weeks
Author:
I.S. Robinson
Author:
J.N. Schwarz
Author:
K.J. Trundle
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics