Electronic tracking system for multiplexed fibre grating sensors
Electronic tracking system for multiplexed fibre grating sensors
We demonstrate for the first time an electronic lock-in system using an acousto-optic tunable filter (AOTF) to track the wavelength of a fibre Bragg grating. The system has an output frequency proportional to the grating wavelength. Initial results show microstrain resolution at data acquisition rates of 10 Hz.
1006-1007
Geiger, H.
ed078c74-a1f0-4816-aee5-6adec67b9ed3
Xu, M.G.
9cd111ff-5235-42c8-8a89-47899e7e8a26
Eaton, N.C.
73e67e0f-1812-40c1-bcd4-372d882dbcc2
Dakin, J.P.
04891b9b-5fb5-4245-879e-9e7361adf904
1995
Geiger, H.
ed078c74-a1f0-4816-aee5-6adec67b9ed3
Xu, M.G.
9cd111ff-5235-42c8-8a89-47899e7e8a26
Eaton, N.C.
73e67e0f-1812-40c1-bcd4-372d882dbcc2
Dakin, J.P.
04891b9b-5fb5-4245-879e-9e7361adf904
Geiger, H., Xu, M.G., Eaton, N.C. and Dakin, J.P.
(1995)
Electronic tracking system for multiplexed fibre grating sensors.
Electronics Letters, 31 (12), .
(doi:10.1049/el:19950641).
Abstract
We demonstrate for the first time an electronic lock-in system using an acousto-optic tunable filter (AOTF) to track the wavelength of a fibre Bragg grating. The system has an output frequency proportional to the grating wavelength. Initial results show microstrain resolution at data acquisition rates of 10 Hz.
Full text not available from this repository.
More information
Published date: 1995
Identifiers
Local EPrints ID: 78143
URI: https://eprints.soton.ac.uk/id/eprint/78143
ISSN: 0013-5194
PURE UUID: 737db4ef-ff7f-44ee-96cb-2cc6e962aeb1
Catalogue record
Date deposited: 11 Mar 2010
Last modified: 18 Jul 2017 23:26
Export record
Altmetrics
Contributors
Author:
H. Geiger
Author:
M.G. Xu
Author:
N.C. Eaton
University divisions
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics