The University of Southampton
University of Southampton Institutional Repository

Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration

Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration
Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration
Background: acute exposures of the hand to vibration result in changes in finger blood flow, but it is not clear how the changes depend on the characteristics of the vibration.
Objectives: to determine the effects of the magnitude and frequency of hand-transmitted vibration on finger blood flow in an exposed and a non-exposed hand during and after exposure to vibration.
Methods: twelve persons attended seven sessions consisting of five successive periods: (1) no force and no vibration, (2) force and no vibration, (3) force and vibration, (4) force and no vibration, and (5) no force and no vibration. During the second, third and fourth periods, the palm of the right hand applied a 2-N downward force on a 25-mm diameter convex platform. During the third period, the platform was vibrated at either 16, 31.5, 63, 125, 250, or 315 Hz with the vibration magnitude increasing linearly from 0 to 15 ms?2 rms (frequency-weighted) over 30 min (0–11 ms?2 rms at 315 Hz). Finger blood flow was measured in the middle and little fingers of the right (exposed) hand and the middle finger of the left (unexposed) hand.
Results: the application of 2-N force by the palm did not affect finger blood flow on either the exposed hand or the unexposed hand. Blood flow in all three fingers (both exposed and not exposed to vibration) reduced similarly with increasing vibration magnitude, with the greatest reduction to about 40% of finger blood flow before vibration exposure. During vibration at the same frequency-weighted acceleration according to current standards, finger blood flow was dependent on the vibration frequency, with vibration at 125, 250 and 315 Hz causing the greatest reductions in finger blood flow. With vibration at 250 Hz and 315 Hz, frequency-weighted accelerations less than 1.0 ms?2 rms reduced finger blood flow, whereas greater magnitudes were required at the lower frequencies. After the cessation of vibration, finger blood flow in exposed and unexposed fingers also depended on the vibration frequency, with greater vasoconstriction after exposure to the higher frequencies.
Conclusions: during exposure to vibration, vasoconstriction in the fingers depends on both the frequency and the magnitude of the vibration. Finger blood flow was reduced by vibration magnitudes much lower than those on many powered hand tools. Vibration of one hand produced a similar vasoconstriction in fingers on the exposed and unexposed hand, suggesting a centrally mediated response. After cessation of vibration, there is continued vasoconstriction that depends on the frequency and magnitude of the prior vibration, with a similar effect in exposed and non-exposed hands
0340-0131
1151-1162
Thompson, Alexandra J.L.
7f28c6d3-ad4b-437c-bf88-bc1dc61fd2ce
Griffin, Michael J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Thompson, Alexandra J.L.
7f28c6d3-ad4b-437c-bf88-bc1dc61fd2ce
Griffin, Michael J.
24112494-9774-40cb-91b7-5b4afe3c41b8

Thompson, Alexandra J.L. and Griffin, Michael J. (2009) Effect of the magnitude and frequency of hand-transmitted vibration on finger blood flow during and after exposure to vibration. International Archives of Occupational and Environmental Health, 82 (9), 1151-1162. (doi:10.1007/s00420-009-0413-x).

Record type: Article

Abstract

Background: acute exposures of the hand to vibration result in changes in finger blood flow, but it is not clear how the changes depend on the characteristics of the vibration.
Objectives: to determine the effects of the magnitude and frequency of hand-transmitted vibration on finger blood flow in an exposed and a non-exposed hand during and after exposure to vibration.
Methods: twelve persons attended seven sessions consisting of five successive periods: (1) no force and no vibration, (2) force and no vibration, (3) force and vibration, (4) force and no vibration, and (5) no force and no vibration. During the second, third and fourth periods, the palm of the right hand applied a 2-N downward force on a 25-mm diameter convex platform. During the third period, the platform was vibrated at either 16, 31.5, 63, 125, 250, or 315 Hz with the vibration magnitude increasing linearly from 0 to 15 ms?2 rms (frequency-weighted) over 30 min (0–11 ms?2 rms at 315 Hz). Finger blood flow was measured in the middle and little fingers of the right (exposed) hand and the middle finger of the left (unexposed) hand.
Results: the application of 2-N force by the palm did not affect finger blood flow on either the exposed hand or the unexposed hand. Blood flow in all three fingers (both exposed and not exposed to vibration) reduced similarly with increasing vibration magnitude, with the greatest reduction to about 40% of finger blood flow before vibration exposure. During vibration at the same frequency-weighted acceleration according to current standards, finger blood flow was dependent on the vibration frequency, with vibration at 125, 250 and 315 Hz causing the greatest reductions in finger blood flow. With vibration at 250 Hz and 315 Hz, frequency-weighted accelerations less than 1.0 ms?2 rms reduced finger blood flow, whereas greater magnitudes were required at the lower frequencies. After the cessation of vibration, finger blood flow in exposed and unexposed fingers also depended on the vibration frequency, with greater vasoconstriction after exposure to the higher frequencies.
Conclusions: during exposure to vibration, vasoconstriction in the fingers depends on both the frequency and the magnitude of the vibration. Finger blood flow was reduced by vibration magnitudes much lower than those on many powered hand tools. Vibration of one hand produced a similar vasoconstriction in fingers on the exposed and unexposed hand, suggesting a centrally mediated response. After cessation of vibration, there is continued vasoconstriction that depends on the frequency and magnitude of the prior vibration, with a similar effect in exposed and non-exposed hands

This record has no associated files available for download.

More information

Published date: October 2009
Organisations: Human Sciences Group

Identifiers

Local EPrints ID: 79054
URI: http://eprints.soton.ac.uk/id/eprint/79054
ISSN: 0340-0131
PURE UUID: 948decfe-9fe2-40bc-bc8d-3627a9ee4cbe
ORCID for Michael J. Griffin: ORCID iD orcid.org/0000-0003-0743-9502

Catalogue record

Date deposited: 12 Mar 2010
Last modified: 14 Mar 2024 00:27

Export record

Altmetrics

Contributors

Author: Alexandra J.L. Thompson
Author: Michael J. Griffin ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×