Microchannel-enabled mitigation of concentration polarization in pervaporation through transport intensification
Microchannel-enabled mitigation of concentration polarization in pervaporation through transport intensification
Pervaporation (PV) efficiency is often hindered by liquid-phase boundary layer mass transfer resistance and concentration polarization. In this study, an ethanol–water system and a polyvinyl alcohol (PVA) membrane were used to systematically investigate the effect of microchannel dimensions on mitigating these limitations. Reducing the channel width from 3 mm to 0.5 mm (at 75 °C, 10 wt% water) increased the permeation flux by 43.4% (from 0.76 to 1.09 kg/(m2∙h)) and improved the separation factor by 163.5%. The concentration polarization factor increased from 0.66 to 0.85, indicating a substantial reduction in mass transfer resistance. The performance leap is attributed to the high flow velocity and strong shear forces within microchannels, which thin the liquid-phase boundary layer and shift the rate-controlling step from liquid-phase diffusion to membrane diffusion. Although increasing temperature from 55 °C to 75 °C surged the permeation flux by 241.5%, it also intensified concentration polarization. In contrast, higher feed water content reduced the separation factor due to membrane swelling but increased the polarization factor toward unity by mitigating liquid-phase supply pressure. A mass transfer model based on Fick’s diffusion law was established to quantify the concentration polarization factor, providing a theoretical foundation for the microfluidic design of intensified pervaporation modules.
Concentration polarization, Mass transfer, Membrane separation, Microchannel, Pervaporation
Kong, Linghao
0dd20db6-5772-4ffd-9dee-6df0c5880878
Li, Guici
fdac29b1-34d2-4614-a295-9e17940eb200
Kou, Chenhui
8ae455d0-12b6-4c0e-be5f-2a932fbe9a50
Li, Xiaoting
23b519ea-d56f-450d-84e5-f5bd371516af
Zhang, Xunli
d7cf1181-3276-4da1-9150-e212b333abb1
Jie, Haoyu
b42891e0-7596-4170-b82b-522934e62567
Jin, Nan
4c238610-7344-4b96-aeef-f039b663691c
Chen, Ying
53a2121b-f974-4b91-b981-ba3e4945c6db
Wang, Qingqiang
9fcf20bc-ee0e-4095-8733-303e9c53b4bc
Zhao, Yuchao
0b5eafdf-0011-4a02-840f-e5b88b61a708
26 March 2026
Kong, Linghao
0dd20db6-5772-4ffd-9dee-6df0c5880878
Li, Guici
fdac29b1-34d2-4614-a295-9e17940eb200
Kou, Chenhui
8ae455d0-12b6-4c0e-be5f-2a932fbe9a50
Li, Xiaoting
23b519ea-d56f-450d-84e5-f5bd371516af
Zhang, Xunli
d7cf1181-3276-4da1-9150-e212b333abb1
Jie, Haoyu
b42891e0-7596-4170-b82b-522934e62567
Jin, Nan
4c238610-7344-4b96-aeef-f039b663691c
Chen, Ying
53a2121b-f974-4b91-b981-ba3e4945c6db
Wang, Qingqiang
9fcf20bc-ee0e-4095-8733-303e9c53b4bc
Zhao, Yuchao
0b5eafdf-0011-4a02-840f-e5b88b61a708
Kong, Linghao, Li, Guici, Kou, Chenhui, Li, Xiaoting, Zhang, Xunli, Jie, Haoyu, Jin, Nan, Chen, Ying, Wang, Qingqiang and Zhao, Yuchao
(2026)
Microchannel-enabled mitigation of concentration polarization in pervaporation through transport intensification.
Chemical Engineering Science, 330, [123859].
(doi:10.1016/j.ces.2026.123859).
Abstract
Pervaporation (PV) efficiency is often hindered by liquid-phase boundary layer mass transfer resistance and concentration polarization. In this study, an ethanol–water system and a polyvinyl alcohol (PVA) membrane were used to systematically investigate the effect of microchannel dimensions on mitigating these limitations. Reducing the channel width from 3 mm to 0.5 mm (at 75 °C, 10 wt% water) increased the permeation flux by 43.4% (from 0.76 to 1.09 kg/(m2∙h)) and improved the separation factor by 163.5%. The concentration polarization factor increased from 0.66 to 0.85, indicating a substantial reduction in mass transfer resistance. The performance leap is attributed to the high flow velocity and strong shear forces within microchannels, which thin the liquid-phase boundary layer and shift the rate-controlling step from liquid-phase diffusion to membrane diffusion. Although increasing temperature from 55 °C to 75 °C surged the permeation flux by 241.5%, it also intensified concentration polarization. In contrast, higher feed water content reduced the separation factor due to membrane swelling but increased the polarization factor toward unity by mitigating liquid-phase supply pressure. A mass transfer model based on Fick’s diffusion law was established to quantify the concentration polarization factor, providing a theoretical foundation for the microfluidic design of intensified pervaporation modules.
Text
CES-D-26-01057_R1 Mitigation of Concentration Polarization_accepted
- Accepted Manuscript
Restricted to Repository staff only until 25 March 2027.
Request a copy
More information
Accepted/In Press date: 24 March 2026
e-pub ahead of print date: 25 March 2026
Published date: 26 March 2026
Keywords:
Concentration polarization, Mass transfer, Membrane separation, Microchannel, Pervaporation
Identifiers
Local EPrints ID: 512164
URI: https://eprints.soton.ac.uk/id/eprint/512164
ISSN: 0009-2509
PURE UUID: e4b5fe35-0e32-4b34-8d21-1eb32b77bdee
Catalogue record
Date deposited: 17 Jun 2026 16:56
Last modified: 13 Sep 2026 15:49
Export record
Altmetrics
Contributors
Author:
Linghao Kong
Author:
Guici Li
Author:
Chenhui Kou
Author:
Xiaoting Li
Author:
Haoyu Jie
Author:
Nan Jin
Author:
Ying Chen
Author:
Qingqiang Wang
Author:
Yuchao Zhao
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.