Electric traction is central to railway decarbonisation; however, significant challenges remain regarding the cost and delivery of electrification. In the UK, Overhead Line Electrification (OLE) infrastructure has contributed to major cost and programme overruns, with the Great Western Electrification Programme increasing from an initial estimate of approximately £1 billion to £2.8 billion, while only partially achieving its original scope. These challenges arise, in part, from uncertainties in the structural loads transmitted to foundations. Improved understanding of these loads and associated displacements, particularly the dynamic components arising from wind and train loading, is therefore essential to reducing uncertainty in the in-service behaviour of OLE structures.
To address these challenges, a suite of instrumentation was developed to record synchronised wind velocities, structural strains, and accelerations on in-service OLE structures. Preliminary deployment in a non-operational setting informed the refinement of instrumentation and methodology prior to installation at three sites across the UK rail network. The monitoring system enabled quantification of wind loading effects for comparison with design code based calculations, as well as assessment of structural dynamic response to passing trains. Strain gauges were installed at the base of the structures to measure bending strains, while accelerometers were used to assess structural displacements resulting from both wind excitation and train induced loading.
Strain data collected from five instrumented structures were analysed alongside concurrent wind speed and direction measurements to evaluate the relationship between wind loading and structural response. Predicted strains, calculated from measured wind speeds using projected mast and conductor areas, were compared with measured values. Across all sites, measured strains were consistently lower than corresponding factored design code predictions. A strong correlation was observed between wind speed, particularly the across-track component, and strain response at the base of the structures. This relationship was further enhanced through the application of moving averages, which reduced measurement noise and improved statistical correlation, albeit with some reduction in peak values.
Frequency analysis of the strain data demonstrated that the dominant vibration modes observed in the field closely align with those identified from accelerometer and displacement measurements. Accelerometer data indicate that train induced loading produces significant dynamic response in the instrumented UC152 and UC203 structures, although magnitudes remain below those implied by current UK rail design standards. Wind induced displacements were generally small, with peak values significantly below the allowable deflection limits specified in OLE design standards.
University of Southampton
John, Oliver Anthony
c5834b7c-1c9e-4b38-9ec3-41d92717db64
John, Oliver Anthony
c5834b7c-1c9e-4b38-9ec3-41d92717db64
Richards, David
a58ea81e-443d-4dab-8d97-55d76a43d57e
Powrie, William
600c3f02-00f8-4486-ae4b-b4fc8ec77c3c
Stainton, Richard
f4e9ee50-3b7e-479d-9a2a-8a6f06977dc8
John, Oliver Anthony
(2026)
An investigation into wind loading on railway overhead line electrification structures.
University of Southampton, Doctoral Thesis, 274pp.
Record type:
Thesis
(Doctoral)
Abstract
Electric traction is central to railway decarbonisation; however, significant challenges remain regarding the cost and delivery of electrification. In the UK, Overhead Line Electrification (OLE) infrastructure has contributed to major cost and programme overruns, with the Great Western Electrification Programme increasing from an initial estimate of approximately £1 billion to £2.8 billion, while only partially achieving its original scope. These challenges arise, in part, from uncertainties in the structural loads transmitted to foundations. Improved understanding of these loads and associated displacements, particularly the dynamic components arising from wind and train loading, is therefore essential to reducing uncertainty in the in-service behaviour of OLE structures.
To address these challenges, a suite of instrumentation was developed to record synchronised wind velocities, structural strains, and accelerations on in-service OLE structures. Preliminary deployment in a non-operational setting informed the refinement of instrumentation and methodology prior to installation at three sites across the UK rail network. The monitoring system enabled quantification of wind loading effects for comparison with design code based calculations, as well as assessment of structural dynamic response to passing trains. Strain gauges were installed at the base of the structures to measure bending strains, while accelerometers were used to assess structural displacements resulting from both wind excitation and train induced loading.
Strain data collected from five instrumented structures were analysed alongside concurrent wind speed and direction measurements to evaluate the relationship between wind loading and structural response. Predicted strains, calculated from measured wind speeds using projected mast and conductor areas, were compared with measured values. Across all sites, measured strains were consistently lower than corresponding factored design code predictions. A strong correlation was observed between wind speed, particularly the across-track component, and strain response at the base of the structures. This relationship was further enhanced through the application of moving averages, which reduced measurement noise and improved statistical correlation, albeit with some reduction in peak values.
Frequency analysis of the strain data demonstrated that the dominant vibration modes observed in the field closely align with those identified from accelerometer and displacement measurements. Accelerometer data indicate that train induced loading produces significant dynamic response in the instrumented UC152 and UC203 structures, although magnitudes remain below those implied by current UK rail design standards. Wind induced displacements were generally small, with peak values significantly below the allowable deflection limits specified in OLE design standards.
Text
OAJohnSouthamptonPhDThesisFinal
- Version of Record
Restricted to Repository staff only until 21 December 2026.
Text
DIN EN 1991-1-4NA DIN Deutsches Institut fur Normung e. V. response
Restricted to Repository staff only
Text
Final-thesis-submission-Examination-Mr-Oliver-John
Restricted to Repository staff only
More information
Accepted/In Press date: 2026
Identifiers
Local EPrints ID: 512332
URI: https://eprints.soton.ac.uk/id/eprint/512332
PURE UUID: c72db1c1-7a26-4c2f-9925-93c2c60e2db2
Catalogue record