The University of Southampton
University of Southampton Institutional Repository

Low-cost colourimetric biosensing using laser-patterned cellophane-based fluidic devices

Low-cost colourimetric biosensing using laser-patterned cellophane-based fluidic devices
Low-cost colourimetric biosensing using laser-patterned cellophane-based fluidic devices
Cellophane is an attractive low-cost substrate for environmentally sustainable fluidic devices because it is biodegradable. Here, we report a laser direct-write (LDW) method, which relies on the principle of photo-polymerisation of a light-sensitive polymer for rapid fabrication of cellophane-based fluidic devices. In this method, a photo-polymer is first deposited on a cellophane substrate in a user-defined pattern and subsequently illuminated using a 405 nm laser to photo-polymerise the pre-deposited patterns and form hydrophobic polymer structures that form the walls of open wells and enclosed flow channels. By tuning the photo-polymer deposition speeds and deposition–photo-polymerisation cycles, polymerised structures with widths of 0.5–2 mm and heights of 0.1–2 mm were reproducibly fabricated on both uncoated and polymer-coated cellophane. Enclosed flow channels with coated cellophane as both layers supported pump-driven flow at 50–250 µL min⁻¹, while hybrid channels with an uncoated bottom layer and coated top layer enabled pump-free capillary transport. Quantitative colourimetric detection of glucose (GOx/HRP–o-dianisidine assay) and nitrite (Griess reaction) was implemented within open wells. The limit-of-detection and limit-of-quantification was 7.31/23.8 µg mL−1 and 6.57/21.9 µM across the ranges of 10–100 µg mL−1 and 5–200 µM for glucose and nitrite respectively. We also report the detection of glucose and nitrite in artificial urine samples within both open well and enclosed flow channels. This LDW-based fabrication approach provides a practical and flexible route for rapid prototyping of disposable cellophane-based fluidic devices for colourimetric sensing.
Colourimetric assay, Nitrite, cellophane, glucose, laser direct-write, photo-polymerisation, point-of-care diagnostics
2590-1370
Ali, Ahsan
60b01a70-c947-4527-a942-9126af541be0
Galanis, Panagiotis
4457b788-deef-4293-ab39-76f501b9529d
McQuillan, Jonathan
9abf6b77-d4bc-44c4-bc38-5f6ad6a26a7e
Saeed, Kordo
87cb67e5-71e8-4759-bf23-2ea00ebd8b39
Dushianthan, Ahilanandan
013692a2-cf26-4278-80bd-9d8fcdb17751
Sivaraman, Gopalan K.
308ebfc2-f6e7-43f2-893f-952c1772285f
Sones, Collin I.
9de9d8ee-d394-46a5-80b7-e341c0eed0a8
Ali, Ahsan
60b01a70-c947-4527-a942-9126af541be0
Galanis, Panagiotis
4457b788-deef-4293-ab39-76f501b9529d
McQuillan, Jonathan
9abf6b77-d4bc-44c4-bc38-5f6ad6a26a7e
Saeed, Kordo
87cb67e5-71e8-4759-bf23-2ea00ebd8b39
Dushianthan, Ahilanandan
013692a2-cf26-4278-80bd-9d8fcdb17751
Sivaraman, Gopalan K.
308ebfc2-f6e7-43f2-893f-952c1772285f
Sones, Collin I.
9de9d8ee-d394-46a5-80b7-e341c0eed0a8

Ali, Ahsan, Galanis, Panagiotis, McQuillan, Jonathan, Saeed, Kordo, Dushianthan, Ahilanandan, Sivaraman, Gopalan K. and Sones, Collin I. (2026) Low-cost colourimetric biosensing using laser-patterned cellophane-based fluidic devices. BIOSENSORS AND BIOELECTRONICS X, 31, [100809]. (doi:10.1016/j.biosx.2026.100809).

Record type: Article

Abstract

Cellophane is an attractive low-cost substrate for environmentally sustainable fluidic devices because it is biodegradable. Here, we report a laser direct-write (LDW) method, which relies on the principle of photo-polymerisation of a light-sensitive polymer for rapid fabrication of cellophane-based fluidic devices. In this method, a photo-polymer is first deposited on a cellophane substrate in a user-defined pattern and subsequently illuminated using a 405 nm laser to photo-polymerise the pre-deposited patterns and form hydrophobic polymer structures that form the walls of open wells and enclosed flow channels. By tuning the photo-polymer deposition speeds and deposition–photo-polymerisation cycles, polymerised structures with widths of 0.5–2 mm and heights of 0.1–2 mm were reproducibly fabricated on both uncoated and polymer-coated cellophane. Enclosed flow channels with coated cellophane as both layers supported pump-driven flow at 50–250 µL min⁻¹, while hybrid channels with an uncoated bottom layer and coated top layer enabled pump-free capillary transport. Quantitative colourimetric detection of glucose (GOx/HRP–o-dianisidine assay) and nitrite (Griess reaction) was implemented within open wells. The limit-of-detection and limit-of-quantification was 7.31/23.8 µg mL−1 and 6.57/21.9 µM across the ranges of 10–100 µg mL−1 and 5–200 µM for glucose and nitrite respectively. We also report the detection of glucose and nitrite in artificial urine samples within both open well and enclosed flow channels. This LDW-based fabrication approach provides a practical and flexible route for rapid prototyping of disposable cellophane-based fluidic devices for colourimetric sensing.

Text
main (32) - Version of Record
Available under License Creative Commons Attribution.
Download (12MB)

More information

Submitted date: 14 April 2026
Accepted/In Press date: 17 June 2026
e-pub ahead of print date: 22 June 2026
Published date: 24 June 2026
Keywords: Colourimetric assay, Nitrite, cellophane, glucose, laser direct-write, photo-polymerisation, point-of-care diagnostics

Identifiers

Local EPrints ID: 512405
URI: https://eprints.soton.ac.uk/id/eprint/512405
ISSN: 2590-1370
PURE UUID: f1800846-d078-40fb-8407-178f8a91f664
ORCID for Ahsan Ali: ORCID iD orcid.org/0009-0004-6574-9220
ORCID for Panagiotis Galanis: ORCID iD orcid.org/0000-0002-2028-5803
ORCID for Kordo Saeed: ORCID iD orcid.org/0000-0003-0123-0302
ORCID for Ahilanandan Dushianthan: ORCID iD orcid.org/0000-0002-0165-3359
ORCID for Collin I. Sones: ORCID iD orcid.org/0000-0002-3738-7662

Catalogue record

Date deposited: 29 Jun 2026 16:43
Last modified: 13 Sep 2026 15:49

Export record

Altmetrics

Contributors

Author: Ahsan Ali ORCID iD
Author: Panagiotis Galanis ORCID iD
Author: Jonathan McQuillan
Author: Kordo Saeed ORCID iD
Author: Ahilanandan Dushianthan ORCID iD
Author: Gopalan K. Sivaraman
Author: Collin I. Sones ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of https://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×