The University of Southampton
University of Southampton Institutional Repository

Coupled on-line in crystallo UV-Vis absorption spectroscopy and X-ray crystallography to compare specific radiation damage in metal-containing proteins at room versus cryogenic temperature

Coupled on-line in crystallo UV-Vis absorption spectroscopy and X-ray crystallography to compare specific radiation damage in metal-containing proteins at room versus cryogenic temperature
Coupled on-line in crystallo UV-Vis absorption spectroscopy and X-ray crystallography to compare specific radiation damage in metal-containing proteins at room versus cryogenic temperature

Specific radiation damage (SRD) to proteins is a pertinent issue discovered duringthe development of cryo-crystallography at synchrotrons, often affecting the macromolecular active site and thus complicating the understanding of mechanistic insights from structural analysis. For proteins with a spectroscopic signature in the visible light spectrum, in crystallo UV-Vis absorption spectroscopy has regularly been used to estimate the dose scale of specific damage build-up and to develop diffraction data-collection strategies to mitigate its effects. Using a coupled spectroscopic and crystallographic approach, here we show that for two metal-containing proteins the structural response to X-ray-induced reduction of metals in their active site is markedly different at room temperature than at cryogenic temperature. This suggests that the use of controlled specific radiation damage to mimic and study a physiological redox transition in a metal-containing protein by X-ray crystallography should preferably be performed at room temperature rather than at cryogenic temperature.

in crystallo UV-Vis absorption spectroscopy, metal-containing proteins, room-temperature X-ray crystallography, specific radiation damage
2059-7983
187-198
Caramello, Nicolas
44b85f28-c66c-4e70-a4ab-c8efe07543f8
Rose, Samuel L.
187f9b11-2f87-4939-ad06-115826504c6b
Mathieu, Eric
abc89c7d-bf0c-48c6-a390-2dc3e5616be1
Petit, Lucas
808d0c23-744d-46cd-a110-08122ab1ebf1
Tews, Ivo
9117fc5e-d01c-4f8d-a734-5b14d3eee8dd
Engilberge, Sylvain
845c9e80-ee35-4d1e-9490-549ac64705fe
Royant, Antoine
96dd9b8f-12f9-4b8f-a80b-02f76a0a41de
Caramello, Nicolas
44b85f28-c66c-4e70-a4ab-c8efe07543f8
Rose, Samuel L.
187f9b11-2f87-4939-ad06-115826504c6b
Mathieu, Eric
abc89c7d-bf0c-48c6-a390-2dc3e5616be1
Petit, Lucas
808d0c23-744d-46cd-a110-08122ab1ebf1
Tews, Ivo
9117fc5e-d01c-4f8d-a734-5b14d3eee8dd
Engilberge, Sylvain
845c9e80-ee35-4d1e-9490-549ac64705fe
Royant, Antoine
96dd9b8f-12f9-4b8f-a80b-02f76a0a41de

Caramello, Nicolas, Rose, Samuel L., Mathieu, Eric, Petit, Lucas, Tews, Ivo, Engilberge, Sylvain and Royant, Antoine (2026) Coupled on-line in crystallo UV-Vis absorption spectroscopy and X-ray crystallography to compare specific radiation damage in metal-containing proteins at room versus cryogenic temperature. Acta Crystallographica Section D: Structural Biology, 82, 187-198. (doi:10.1107/S2059798326000690).

Record type: Article

Abstract

Specific radiation damage (SRD) to proteins is a pertinent issue discovered duringthe development of cryo-crystallography at synchrotrons, often affecting the macromolecular active site and thus complicating the understanding of mechanistic insights from structural analysis. For proteins with a spectroscopic signature in the visible light spectrum, in crystallo UV-Vis absorption spectroscopy has regularly been used to estimate the dose scale of specific damage build-up and to develop diffraction data-collection strategies to mitigate its effects. Using a coupled spectroscopic and crystallographic approach, here we show that for two metal-containing proteins the structural response to X-ray-induced reduction of metals in their active site is markedly different at room temperature than at cryogenic temperature. This suggests that the use of controlled specific radiation damage to mimic and study a physiological redox transition in a metal-containing protein by X-ray crystallography should preferably be performed at room temperature rather than at cryogenic temperature.

This record has no associated files available for download.

More information

Accepted/In Press date: 23 January 2026
Published date: 5 February 2026
Additional Information: Publisher Copyright: © 2026 Nicolas Caramello et al.
Keywords: in crystallo UV-Vis absorption spectroscopy, metal-containing proteins, room-temperature X-ray crystallography, specific radiation damage

Identifiers

Local EPrints ID: 512468
URI: https://eprints.soton.ac.uk/id/eprint/512468
ISSN: 2059-7983
PURE UUID: b046a0a2-df13-4d29-b5e2-5283be9b6cc9
ORCID for Ivo Tews: ORCID iD orcid.org/0000-0002-4704-1139

Catalogue record

Date deposited: 30 Jun 2026 17:07
Last modified: 13 Sep 2026 15:49

Export record

Altmetrics

Contributors

Author: Nicolas Caramello
Author: Samuel L. Rose
Author: Eric Mathieu
Author: Lucas Petit
Author: Ivo Tews ORCID iD
Author: Sylvain Engilberge
Author: Antoine Royant

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of https://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×