Rapid antimicrobial susceptibility testing directly from positive blood cultures
Rapid antimicrobial susceptibility testing directly from positive blood cultures
Sepsis results from bloodstream infections and is a leading cause of mortality worldwide, accounting for over 10 million deaths annually and imposing a substantial burden on the global economy. Septic shock is a time-sensitive condition in which mortality increases by approximately 8% for every hour of delayed treatment. A key limitation in current sepsis management is the delayed initiation of targeted antimicrobial therapy, primarily due to time-consuming subculturing steps and slow antimicrobial susceptibility testing (AST) methods. In this study, we present a rapid AST workflow performed directly from positive blood cultures within 3 hours. The method integrates a Smart Centrifugation Device for host cell removal and bacterial concentration, with impedance-based flow cytometry (iFAST) for rapid antimicrobial susceptibility testing. This streamlined, partially automated method has the potential to accelerate sepsis diagnosis and facilitate timely, targeted antimicrobial treatment.
University of Southampton
Cancado, Daniel Nathan Tomas
f7f53cb7-a151-4490-ba1a-7c8cac810a07
Morgan, Hywel
de00d59f-a5a2-48c4-a99a-1d5dd7854174
Spencer, Daniel
4affe9f6-353a-4507-8066-0180b8dc9eaf
Osaid, Mohammad
09987150-9ea8-479f-a834-128837a12d61
van der Wijngaart, Wouter
34e14fc7-bb63-4489-aa42-116b8de21c41
Cancado, Daniel Nathan Tomas
f7f53cb7-a151-4490-ba1a-7c8cac810a07
Morgan, Hywel
de00d59f-a5a2-48c4-a99a-1d5dd7854174
Spencer, Daniel
4affe9f6-353a-4507-8066-0180b8dc9eaf
Osaid, Mohammad
09987150-9ea8-479f-a834-128837a12d61
van der Wijngaart, Wouter
34e14fc7-bb63-4489-aa42-116b8de21c41
Cancado, Daniel Nathan Tomas and Osaid, Mohammad
(2026)
Rapid antimicrobial susceptibility testing directly from positive blood cultures.
University of Southampton
doi:10.5258/SOTON/D3752
[Dataset]
Abstract
Sepsis results from bloodstream infections and is a leading cause of mortality worldwide, accounting for over 10 million deaths annually and imposing a substantial burden on the global economy. Septic shock is a time-sensitive condition in which mortality increases by approximately 8% for every hour of delayed treatment. A key limitation in current sepsis management is the delayed initiation of targeted antimicrobial therapy, primarily due to time-consuming subculturing steps and slow antimicrobial susceptibility testing (AST) methods. In this study, we present a rapid AST workflow performed directly from positive blood cultures within 3 hours. The method integrates a Smart Centrifugation Device for host cell removal and bacterial concentration, with impedance-based flow cytometry (iFAST) for rapid antimicrobial susceptibility testing. This streamlined, partially automated method has the potential to accelerate sepsis diagnosis and facilitate timely, targeted antimicrobial treatment.
Spreadsheet
Figure4.xlsx
- Dataset
Spreadsheet
Figure3.xlsx
- Dataset
Spreadsheet
Suppl._Figure2.xlsx
- Dataset
More information
Published date: 13 January 2026
Identifiers
Local EPrints ID: 512568
URI: https://eprints.soton.ac.uk/id/eprint/512568
PURE UUID: 3e44dd99-6705-4bd9-b462-3ff29fdbbb75
Catalogue record
Date deposited: 08 Jul 2026 16:47
Last modified: 12 Nov 2026 03:26
Export record
Altmetrics
Contributors
Creator:
Daniel Nathan Tomas Cancado
Research team head:
Hywel Morgan
Research team head:
Daniel Spencer
Creator:
Mohammad Osaid
Research team head:
Wouter van der Wijngaart
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics