How hyperoxia affects systemic redox state: insights from PULSE-Ox, a randomised double-blind mechanistic feasibility trial
How hyperoxia affects systemic redox state: insights from PULSE-Ox, a randomised double-blind mechanistic feasibility trial
Background Oxygen therapy is ubiquitous in medical practise, but recommendations for administration during surgery are conflicting, and mechanisms of harm are ill-defined. The World Health Organization (WHO) recommends that all anaesthetised patients receive 80% oxygen intraoperatively to reduce surgical site infections. Whether such high oxygen concentrations cause oxidative stress remains uncertain. Methods Adults undergoing major cancer surgery were randomly allocated to conservative (FiO 2=0.3, n =8), typical (FiO 2=0.55, n =10) or recommended (FiO 2=0.8, n =10) oxygen throughout anaesthesia. The aims were to determine whether i) intraoperative oxygen at or below WHO-recommended levels affects whole-body redox state, and ii) redox profiling could distinguish between different oxygen concentrations. Peripheral oxygen saturation (SpO 2) and oxygen reserve index were monitored (co)oximetrically. Paired arterial/central venous blood samples/gases were collected 2-hourly. Lipid peroxides, protein carbonyls, free thiols, antioxidants and nitroso species were quantified using Liquid Chromatography-Tandem Mass Spectrometry, Enzyme-Linked Immunosorbent Assay (ELISA), colourimetry and gas-phase chemiluminescence. Results Double-blinded recruitment of 28 patients (median age 65.8 yr) to three different intraoperative oxygen concentrations was feasible and successful during the study period from September, 2018 to May 2021. While SpO 2 remained unchanged, systemic oxygen utilisation paradoxically decreased with higher oxygen concentrations ( P =0.0006). While free thiol levels rose moderately, nitrosation increased significantly ( P =0.039/0.002/0.039 for FiO 2=0.3/0.55/0.8). Administration of 80% oxygen was associated with diminished reductive power ( P =0.012) and significant oxidative stress ( P =0.004). Conclusions Cross-sectional redox profiling may allow early identification of patients at risk of postoperative complications, while longitudinal profiling may distinguish between oxygen intervention groups. High oxygen concentrations challenge the body’s ability to maintain redox balance, potentially increasing vulnerability to other stressors. Our results lay the foundation for large clinical effectiveness studies evaluating oxygen therapy targets and suggest that ‘redox scoring’ could guide individualised oxygen administration. Trial registration number NCT03552627 ( Clinicaltrials.gov
cancer, hyperoxia, oxidative stress, personalised medicine, redox balance, surgical stress
Cumpstey, Andrew F.
050a389c-f550-4453-a80a-f1a6e57db923
Clark, Anna D.
448206a0-fb07-4935-ae3e-0516c54b661c
Minnion, Magdalena
ab23b32b-9f8e-4876-aaf5-99cb6a725a2f
Crosby, Siobhan F.
a3dec286-536c-4e2c-a22f-8ddf0fc2d1da
Nogueira, Renato C.
a66730d5-8f53-4a9d-8c5a-4daf96ba497c
Moyses, Helen
56434d9c-870f-4539-a66a-c791add44f67
Martin, Daniel
95bea496-441a-4a08-8ea4-aabb9eb421d4
Tanus-Santos, José E.
e526139d-eadc-473f-84bd-5bcb2104876e
Jackson, Alan A.
c9a12d7c-b4d6-4c92-820e-890a688379ef
Edwards, Mark
818201d5-7636-4292-9af8-7dd8bcd1fcb5
Grocott, Michael P.W.
1e87b741-513e-4a22-be13-0f7bb344e8c2
Feelisch, Martin
8c1b9965-8614-4e85-b2c6-458a2e17eafd
1 June 2026
Cumpstey, Andrew F.
050a389c-f550-4453-a80a-f1a6e57db923
Clark, Anna D.
448206a0-fb07-4935-ae3e-0516c54b661c
Minnion, Magdalena
ab23b32b-9f8e-4876-aaf5-99cb6a725a2f
Crosby, Siobhan F.
a3dec286-536c-4e2c-a22f-8ddf0fc2d1da
Nogueira, Renato C.
a66730d5-8f53-4a9d-8c5a-4daf96ba497c
Moyses, Helen
56434d9c-870f-4539-a66a-c791add44f67
Martin, Daniel
95bea496-441a-4a08-8ea4-aabb9eb421d4
Tanus-Santos, José E.
e526139d-eadc-473f-84bd-5bcb2104876e
Jackson, Alan A.
c9a12d7c-b4d6-4c92-820e-890a688379ef
Edwards, Mark
818201d5-7636-4292-9af8-7dd8bcd1fcb5
Grocott, Michael P.W.
1e87b741-513e-4a22-be13-0f7bb344e8c2
Feelisch, Martin
8c1b9965-8614-4e85-b2c6-458a2e17eafd
Cumpstey, Andrew F., Clark, Anna D., Minnion, Magdalena, Crosby, Siobhan F., Nogueira, Renato C., Moyses, Helen, Martin, Daniel, Tanus-Santos, José E., Jackson, Alan A., Edwards, Mark, Grocott, Michael P.W. and Feelisch, Martin
(2026)
How hyperoxia affects systemic redox state: insights from PULSE-Ox, a randomised double-blind mechanistic feasibility trial.
BJA Open, 18, [100563].
(doi:10.1016/j.bjao.2026.100563).
Abstract
Background Oxygen therapy is ubiquitous in medical practise, but recommendations for administration during surgery are conflicting, and mechanisms of harm are ill-defined. The World Health Organization (WHO) recommends that all anaesthetised patients receive 80% oxygen intraoperatively to reduce surgical site infections. Whether such high oxygen concentrations cause oxidative stress remains uncertain. Methods Adults undergoing major cancer surgery were randomly allocated to conservative (FiO 2=0.3, n =8), typical (FiO 2=0.55, n =10) or recommended (FiO 2=0.8, n =10) oxygen throughout anaesthesia. The aims were to determine whether i) intraoperative oxygen at or below WHO-recommended levels affects whole-body redox state, and ii) redox profiling could distinguish between different oxygen concentrations. Peripheral oxygen saturation (SpO 2) and oxygen reserve index were monitored (co)oximetrically. Paired arterial/central venous blood samples/gases were collected 2-hourly. Lipid peroxides, protein carbonyls, free thiols, antioxidants and nitroso species were quantified using Liquid Chromatography-Tandem Mass Spectrometry, Enzyme-Linked Immunosorbent Assay (ELISA), colourimetry and gas-phase chemiluminescence. Results Double-blinded recruitment of 28 patients (median age 65.8 yr) to three different intraoperative oxygen concentrations was feasible and successful during the study period from September, 2018 to May 2021. While SpO 2 remained unchanged, systemic oxygen utilisation paradoxically decreased with higher oxygen concentrations ( P =0.0006). While free thiol levels rose moderately, nitrosation increased significantly ( P =0.039/0.002/0.039 for FiO 2=0.3/0.55/0.8). Administration of 80% oxygen was associated with diminished reductive power ( P =0.012) and significant oxidative stress ( P =0.004). Conclusions Cross-sectional redox profiling may allow early identification of patients at risk of postoperative complications, while longitudinal profiling may distinguish between oxygen intervention groups. High oxygen concentrations challenge the body’s ability to maintain redox balance, potentially increasing vulnerability to other stressors. Our results lay the foundation for large clinical effectiveness studies evaluating oxygen therapy targets and suggest that ‘redox scoring’ could guide individualised oxygen administration. Trial registration number NCT03552627 ( Clinicaltrials.gov
Text
PIIS2772609626000377
- Version of Record
More information
Accepted/In Press date: 10 April 2026
e-pub ahead of print date: 28 May 2026
Published date: 1 June 2026
Additional Information:
© 2026 The Author(s).
Keywords:
cancer, hyperoxia, oxidative stress, personalised medicine, redox balance, surgical stress
Identifiers
Local EPrints ID: 512649
URI: https://eprints.soton.ac.uk/id/eprint/512649
ISSN: 2772-6096
PURE UUID: 410e85b8-26a7-4e1f-9077-3a3a8e1926bd
Catalogue record
Date deposited: 14 Jul 2026 16:40
Last modified: 13 Sep 2026 15:49
Export record
Altmetrics
Contributors
Author:
Andrew F. Cumpstey
Author:
Anna D. Clark
Author:
Magdalena Minnion
Author:
Siobhan F. Crosby
Author:
Renato C. Nogueira
Author:
Helen Moyses
Author:
Daniel Martin
Author:
José E. Tanus-Santos
Author:
Mark Edwards
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics