Defining radiological progression in children who have ingested multiple magnets using a novel objective tool applied to abdominal radiographs

Defining radiological progression in children who have ingested multiple magnets using a novel objective tool applied to abdominal radiographs
Defining radiological progression in children who have ingested multiple magnets using a novel objective tool applied to abdominal radiographs

Background: The decision to operate on asymptomatic children who have ingested multiple magnetic objects is based on a subjective assessment of magnet progression via serial abdominal radiographs at non-standardised time-points. We aimed to develop an objective tool to identify non-progression on serial abdominal radiographs. Method: Children (aged ≤16 years) who ingested two or more magnetic objects in one episode were identified from four UK paediatric surgery centres. Asymptomatic children who had undergone two or more abdominal radiographs, without radiological evidence of obstruction or pneumoperitoneum, were included. Each abdominal radiograph was divided into a 3x3 grid and progression was defined as movement of magnets from one grid region to another between two serial radiographs. Magnet-related injuries were recorded. Results: Thirty-one children, ingesting a median of 3 magnets (range: 2–20), were included. Of these 10/31 (32 %) underwent a surgical intervention with 5/31 (16 %) confirmed to have a magnet-related injury. Timing of radiographs varied with 21/31 (68 %) undergoing at least one follow-up radiograph within 24 h and 29/31 (94 %) in the first 48 h. Children with a magnet-related injury had non-progression identified earlier. No child with two consecutive episodes of progression developed a magnet-related injury, whereas two consecutive episodes of non-progression were strongly associated with magnet-related injury. Conclusion: A 3x3 grid system overlaying the abdominal radiograph provides an objective tool to evaluate magnet progression. We suggest an imaging protocol consisting of at least three abdominal radiographs within the first 36–48 h, with risk-based adjustment of imaging frequency thereafter. Combined with standardisation of radiograph timing, the grid system may facilitate earlier intervention in those with non-progression, safe early discharge in those without injury, and overall reduced radiation exposure.

Foreign body ingestion, Magnet ingestion, Pediatric, Radiograph, Surgery
0022-3468
Neville, Jonathan J
b3ae31fa-8d61-4805-a923-b7889b90cbae
Healy, Costa
9e2468e1-44a6-495a-a6a8-c109433189e0
Aldeiri, Bashar
28cd18bf-d81e-460c-b1bb-5368a980ff37
Stibbards, Sarah
267b04c6-a3ba-4ec6-a51e-08a8b19a8dfd
Hall, Nigel
6919e8af-3890-42c1-98a7-c110791957cf
Harwood, Rachel
5c57fde6-e266-4dd6-806b-5491180bdec8
Neville, Jonathan J
b3ae31fa-8d61-4805-a923-b7889b90cbae
Healy, Costa
9e2468e1-44a6-495a-a6a8-c109433189e0
Aldeiri, Bashar
28cd18bf-d81e-460c-b1bb-5368a980ff37
Stibbards, Sarah
267b04c6-a3ba-4ec6-a51e-08a8b19a8dfd
Hall, Nigel
6919e8af-3890-42c1-98a7-c110791957cf
Harwood, Rachel
5c57fde6-e266-4dd6-806b-5491180bdec8

Neville, Jonathan J, Healy, Costa, Aldeiri, Bashar, Stibbards, Sarah, Hall, Nigel and Harwood, Rachel (2026) Defining radiological progression in children who have ingested multiple magnets using a novel objective tool applied to abdominal radiographs. Journal of Pediatric Surgery, 61 (6), [163055]. (doi:10.1016/j.jpedsurg.2026.163055).

Record type: Article

Abstract

Background: The decision to operate on asymptomatic children who have ingested multiple magnetic objects is based on a subjective assessment of magnet progression via serial abdominal radiographs at non-standardised time-points. We aimed to develop an objective tool to identify non-progression on serial abdominal radiographs. Method: Children (aged ≤16 years) who ingested two or more magnetic objects in one episode were identified from four UK paediatric surgery centres. Asymptomatic children who had undergone two or more abdominal radiographs, without radiological evidence of obstruction or pneumoperitoneum, were included. Each abdominal radiograph was divided into a 3x3 grid and progression was defined as movement of magnets from one grid region to another between two serial radiographs. Magnet-related injuries were recorded. Results: Thirty-one children, ingesting a median of 3 magnets (range: 2–20), were included. Of these 10/31 (32 %) underwent a surgical intervention with 5/31 (16 %) confirmed to have a magnet-related injury. Timing of radiographs varied with 21/31 (68 %) undergoing at least one follow-up radiograph within 24 h and 29/31 (94 %) in the first 48 h. Children with a magnet-related injury had non-progression identified earlier. No child with two consecutive episodes of progression developed a magnet-related injury, whereas two consecutive episodes of non-progression were strongly associated with magnet-related injury. Conclusion: A 3x3 grid system overlaying the abdominal radiograph provides an objective tool to evaluate magnet progression. We suggest an imaging protocol consisting of at least three abdominal radiographs within the first 36–48 h, with risk-based adjustment of imaging frequency thereafter. Combined with standardisation of radiograph timing, the grid system may facilitate earlier intervention in those with non-progression, safe early discharge in those without injury, and overall reduced radiation exposure.

Text
R1_clean_manuscript - Accepted Manuscript
Available under License Creative Commons Attribution.
Download (1MB)
Text
Title Page - Accepted Manuscript
Available under License Creative Commons Attribution.
Download (15kB)
Image
Figure 1 - Accepted Manuscript
Available under License Creative Commons Attribution.
Download (75kB)

More information

Accepted/In Press date: 1 March 2026
e-pub ahead of print date: 5 March 2026
Published date: 1 June 2026
Additional Information: Publisher Copyright: © 2026 The Author(s)
Keywords: Foreign body ingestion, Magnet ingestion, Pediatric, Radiograph, Surgery

Identifiers

Local EPrints ID: 513102
URI: https://eprints.soton.ac.uk/id/eprint/513102
ISSN: 0022-3468
PURE UUID: aa9d1681-f8ed-456d-93c8-07186fb2db33
ORCID for Nigel Hall: ORCID iD orcid.org/0000-0001-8570-9374

Catalogue record

Date deposited: 30 Jul 2026 16:55
Last modified: 13 Sep 2026 15:50

Export record

Altmetrics

Contributors

Author: Jonathan J Neville
Author: Costa Healy
Author: Bashar Aldeiri
Author: Sarah Stibbards
Author: Nigel Hall ORCID iD
Author: Rachel Harwood

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of https://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×