The University of Southampton
University of Southampton Institutional Repository

Enhanced photoelectrochemical immunosensing of carcinoembryonic antigen via MoS₂ heterostructure-induced charge separation

Enhanced photoelectrochemical immunosensing of carcinoembryonic antigen via MoS₂ heterostructure-induced charge separation
Enhanced photoelectrochemical immunosensing of carcinoembryonic antigen via MoS₂ heterostructure-induced charge separation

Photoelectrochemical (PEC) biosensors have great potential in the detection of biomarkers in an ultra-sensitive manner. However, many of the PEC biosensors have poor carrier recombination and charge separation. In this project, a PEC Immunosensor based on a MoS₂ heterostructure has been synthesized for detecting carcinoembryonic antigens (CEAs) through the formation of bismuth oxyiodide (BiOI) composite with reduced graphene oxide (rGO). The fabricated rGO/MoS₂/BiOI obtained a greater visible light absorption capacity and an improved band gap of about 1.19 eV facilitating optimum photo-absorption (excitation) under visible light. Upon photoelectrochemical testing, the rGO/MoS₂/BiOI ternary electrode exhibited a photocurrent density of about 25.6 mA which dropped to about 4.0 mA due to the formation of antigen-antibody complexes signifying great charge transfer in the interface. Mott Schottky analysis confirmed the presence of a p-p heterojunction and Z-scheme for the charge transfer system which effectively lowered the recombination rate of the electron-hole pairs. The developed rGO/MoS₂/BiOI PEC immunosensor exhibited excellent stability and selectivity, delivering consistent photocurrent responses under repeated light on/off cycles with minimal interference from other biomolecules. It showed a linear response toward CEA over a wide concentration range (0.01–10 μg/mL) with a low detection limit of 0.01 μg/mL, demonstrating its strong potential for sensitive and reliable biomarker detection. This research demonstrated the promising properties of MoS₂ based heterostructure PEC Immunosensor for early cancer diagnostics.

Cancer biomarker detection, Carcinoembryonic antigen, MoS₂ heterostructure, Photoelectrochemical Immunosensor, Z-scheme charge transfer
0026-265X
Shabbir, Syeda Ammara
3d16fe1a-2755-494b-9f28-39df47c309a5
Shahzad, Amna
bf244578-4edd-49ab-b8cb-833269ec9e22
Farhat, Raheel Shamir
57040fd5-0b02-40b4-a6f6-8e4e2aa3d6b2
Haris, Muhammad
98c70dc3-0711-41e2-8555-ddbeb4c46ffe
Tahir, Maryam
73b09fe4-e8ae-4c5e-8c1a-cf79c21817be
Anjum, Safia
ed89f4a6-ce54-4247-9f3e-8b5df6a5006a
Latif, Hamid
5b079b1f-abce-456b-aec9-5e4cdf31111c
de Leon, Carlos Ponce
508a312e-75ff-4bcb-9151-dacc424d755c
Ullah, Rezwan
5a33fa4e-d4de-4ddb-8c16-8a5b1ae04cc8
Tamulevičius, Tomas
350a51c5-5099-48f9-8fb9-8fcfd94935b8
Tamulevičius, Sigitas
94800a0a-5be4-42ff-b203-5d23b03fcd7c
Shabbir, Syeda Ammara
3d16fe1a-2755-494b-9f28-39df47c309a5
Shahzad, Amna
bf244578-4edd-49ab-b8cb-833269ec9e22
Farhat, Raheel Shamir
57040fd5-0b02-40b4-a6f6-8e4e2aa3d6b2
Haris, Muhammad
98c70dc3-0711-41e2-8555-ddbeb4c46ffe
Tahir, Maryam
73b09fe4-e8ae-4c5e-8c1a-cf79c21817be
Anjum, Safia
ed89f4a6-ce54-4247-9f3e-8b5df6a5006a
Latif, Hamid
5b079b1f-abce-456b-aec9-5e4cdf31111c
de Leon, Carlos Ponce
508a312e-75ff-4bcb-9151-dacc424d755c
Ullah, Rezwan
5a33fa4e-d4de-4ddb-8c16-8a5b1ae04cc8
Tamulevičius, Tomas
350a51c5-5099-48f9-8fb9-8fcfd94935b8
Tamulevičius, Sigitas
94800a0a-5be4-42ff-b203-5d23b03fcd7c

Shabbir, Syeda Ammara, Shahzad, Amna, Farhat, Raheel Shamir, Haris, Muhammad, Tahir, Maryam, Anjum, Safia, Latif, Hamid, de Leon, Carlos Ponce, Ullah, Rezwan, Tamulevičius, Tomas and Tamulevičius, Sigitas (2026) Enhanced photoelectrochemical immunosensing of carcinoembryonic antigen via MoS₂ heterostructure-induced charge separation. Microchemical Journal, 226, [118281]. (doi:10.1016/j.microc.2026.118281).

Record type: Article

Abstract

Photoelectrochemical (PEC) biosensors have great potential in the detection of biomarkers in an ultra-sensitive manner. However, many of the PEC biosensors have poor carrier recombination and charge separation. In this project, a PEC Immunosensor based on a MoS₂ heterostructure has been synthesized for detecting carcinoembryonic antigens (CEAs) through the formation of bismuth oxyiodide (BiOI) composite with reduced graphene oxide (rGO). The fabricated rGO/MoS₂/BiOI obtained a greater visible light absorption capacity and an improved band gap of about 1.19 eV facilitating optimum photo-absorption (excitation) under visible light. Upon photoelectrochemical testing, the rGO/MoS₂/BiOI ternary electrode exhibited a photocurrent density of about 25.6 mA which dropped to about 4.0 mA due to the formation of antigen-antibody complexes signifying great charge transfer in the interface. Mott Schottky analysis confirmed the presence of a p-p heterojunction and Z-scheme for the charge transfer system which effectively lowered the recombination rate of the electron-hole pairs. The developed rGO/MoS₂/BiOI PEC immunosensor exhibited excellent stability and selectivity, delivering consistent photocurrent responses under repeated light on/off cycles with minimal interference from other biomolecules. It showed a linear response toward CEA over a wide concentration range (0.01–10 μg/mL) with a low detection limit of 0.01 μg/mL, demonstrating its strong potential for sensitive and reliable biomarker detection. This research demonstrated the promising properties of MoS₂ based heterostructure PEC Immunosensor for early cancer diagnostics.

Text
main (50) - Version of Record
Available under License Creative Commons Attribution.
Download (8MB)

More information

Accepted/In Press date: 3 May 2026
e-pub ahead of print date: 4 May 2026
Published date: 9 May 2026
Keywords: Cancer biomarker detection, Carcinoembryonic antigen, MoS₂ heterostructure, Photoelectrochemical Immunosensor, Z-scheme charge transfer

Identifiers

Local EPrints ID: 513132
URI: https://eprints.soton.ac.uk/id/eprint/513132
ISSN: 0026-265X
PURE UUID: 4e3fb757-36d6-446f-8ad6-026ca3652303
ORCID for Carlos Ponce de Leon: ORCID iD orcid.org/0000-0002-1907-5913

Catalogue record

Date deposited: 04 Aug 2026 16:31
Last modified: 13 Sep 2026 15:50

Export record

Altmetrics

Contributors

Author: Syeda Ammara Shabbir
Author: Amna Shahzad
Author: Raheel Shamir Farhat
Author: Muhammad Haris
Author: Maryam Tahir
Author: Safia Anjum
Author: Hamid Latif
Author: Rezwan Ullah
Author: Tomas Tamulevičius
Author: Sigitas Tamulevičius

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of https://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×