Estimation of dielectric temperature in buried HVDC cables using reduced-order thermal model
Estimation of dielectric temperature in buried HVDC cables using reduced-order thermal model
This paper presents a superposition-based thermal model that estimates the transient radial temperature distribution in high voltage direct current (HVDC) cable insulation from load current. The total temperature is decomposed into an undisturbed ground component from a one-dimensional diffusion model and a cable-induced perturbation solved by a 32-state radial resistor-capacitor (RC) network with temperature-dependent conductivity and field-dependent dielectric loss. Validated over 300 days against finite element analysis (FEA) (conductor root mean squared error (RMSE) 0.26 ◦C) and continuous distributed temperature sensing (DTS) measurements (RMSE 0.33 ◦C) from a 600 kV bipole submarine cable, the model is further compressed via Proper Orthogonal Decomposition (POD)– Discrete Empirical Interpolation Method (DEIM) to a 4-state system (reduced order model - ROM) that reproduces the insulation temperature drop to within 0.13 ◦C RMSE of 32-states (full order model - FOM), with the required number of modes independent of mesh resolution.
Chaudhary, Sunny
25f0d213-03ef-4909-8cfc-29a8498aa28f
Dix, Justin
efbb0b6e-7dfd-47e1-ae96-92412bd45628
Lewin, Paul
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Callender, George
4189d79e-34c3-422c-a601-95b156c27e76
3 September 2026
Chaudhary, Sunny
25f0d213-03ef-4909-8cfc-29a8498aa28f
Dix, Justin
efbb0b6e-7dfd-47e1-ae96-92412bd45628
Lewin, Paul
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Callender, George
4189d79e-34c3-422c-a601-95b156c27e76
Chaudhary, Sunny, Dix, Justin, Lewin, Paul and Callender, George
(2026)
Estimation of dielectric temperature in buried HVDC cables using reduced-order thermal model.
Record type:
Conference or Workshop Item
(Paper)
Abstract
This paper presents a superposition-based thermal model that estimates the transient radial temperature distribution in high voltage direct current (HVDC) cable insulation from load current. The total temperature is decomposed into an undisturbed ground component from a one-dimensional diffusion model and a cable-induced perturbation solved by a 32-state radial resistor-capacitor (RC) network with temperature-dependent conductivity and field-dependent dielectric loss. Validated over 300 days against finite element analysis (FEA) (conductor root mean squared error (RMSE) 0.26 ◦C) and continuous distributed temperature sensing (DTS) measurements (RMSE 0.33 ◦C) from a 600 kV bipole submarine cable, the model is further compressed via Proper Orthogonal Decomposition (POD)– Discrete Empirical Interpolation Method (DEIM) to a 4-state system (reduced order model - ROM) that reproduces the insulation temperature drop to within 0.13 ◦C RMSE of 32-states (full order model - FOM), with the required number of modes independent of mesh resolution.
Text
Accepted_Manuscript
- Accepted Manuscript
More information
Published date: 3 September 2026
Identifiers
Local EPrints ID: 514132
URI: https://eprints.soton.ac.uk/id/eprint/514132
PURE UUID: 4c9e95cc-5125-47ea-894a-4ea889fd4ad1
Catalogue record
Date deposited: 09 Sep 2026 16:32
Last modified: 13 Sep 2026 15:51
Export record
Contributors
Author:
Sunny Chaudhary
Author:
Paul Lewin
Author:
George Callender
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics