The University of Southampton
University of Southampton Institutional Repository

Investigating the coupling between geometry and thermal gradient of flexible thermoelectric generators

Investigating the coupling between geometry and thermal gradient of flexible thermoelectric generators
Investigating the coupling between geometry and thermal gradient of flexible thermoelectric generators
Flexible thermoelectric generators (f-TEGs) represent a promising technology for harvesting waste heat from ambient sources, including the human body, thereby enabling continuous power delivery for distributed sensors and wearable electronics [1]. However, their implementation as thin-film devices imposes inherent limitations on the achievable output power [2]. Since power generation scales with the number of thermoelectric units, large-area integration facilitated by a commercially viable roll-to-roll (R2R) manufacturing offers a practical route toward energy harvesting in applications such as electronic textiles [3]. Centimetre-scale f-TEGs incorporating multiple p–n pairs, typically on the order of several tens, have been shown to deliver power outputs in the nanowatt range [4]. Although device performance depends not only on electrical and thermal properties but also on geometry and the applied thermal gradient, the interplay among these factors is often underreported in experimental characterisations [5]. Consequently, reported values of output voltage and Seebeck coefficient can be inconsistent and difficult to compare across studies [6,7].

This work reports the characterisation of centimetre-scale f-TEGs, focusing on the influence of device geometry and thermal gradient on the measured open-circuit Seebeck voltage. Devices consisted of a 13 cm × 1 cm polyimide substrate with 12 p-n pairs of Bi₂Te₃ (n-type) and Sb₂Te₃ (p-type) thermoelectric legs connected electrically in series and thermally in parallel, as shown in Figure 1. The devices were mounted between heat sources, T1 and T2 supplied by Peltier modules under fixed input power, establishing a temperature gradient across the generator. The gradient was varied by adjusting the relative position of the Peltier modules to each other, introducing gaps of up to 10 mm along the device length. The open-circuit voltage was measured after 30 minutes of temperature stabilisation using a B1500A Semiconductor Device Analyzer by Aglient Technologies. Importantly, although the input power was fixed, the resulting temperature difference varied with gap configuration due to changes in heat transfer.
For all gap conditions, open-circuit voltage increased linearly with ΔT, which is the expected thermoelectric response described by the Seebeck coefficient, S=ΔV/ΔT , (Figure 2). However, the absolute voltage values varied markedly with the gap size. At a 10 mm gap, the device produced ~16 mV at ΔT ≈ 37 °C, while at full contact (0 mm gap), the voltage increased to ~34 mV at ΔT ≈ 34 °C, representing an increase of more than a factor of 2. This trend persisted across intermediate gap sizes: at ΔT ≈ 30 °C, output voltage consistently decreased with increasing gap size (Figure 3). This behaviour is unexpected, as the Seebeck coefficient is a material-intrinsic parameter and should remain constant for the same ΔT. These preliminary findings suggest that geometric configuration significantly affects thermal coupling and, consequently, the effective voltage response. Further studies are needed to isolate and confirm the mechanisms underlying this observation.

In conclusion, this work highlights the importance of the coupling between geometry and the thermal gradient of f-TEGs for maximising their open-circuit voltage. Optimised coupling will enable design of scalable devices for practical energy harvesting applications.
Hackett, Charlotte
256fe850-451a-4363-9d40-6de60b6f6d14
More, Yash
c70570eb-d495-4c6b-a8a6-e0bab91e40bb
Komolafe, Abiodun
5e79fbab-38be-4a64-94d5-867a94690932
Zeimpekis, Ioannis
a2c354ec-3891-497c-adac-89b3a5d96af0
Morgan, Katrina
2b9605fc-ac61-4ae7-b5f1-b6e3d257701d
Hackett, Charlotte
256fe850-451a-4363-9d40-6de60b6f6d14
More, Yash
c70570eb-d495-4c6b-a8a6-e0bab91e40bb
Komolafe, Abiodun
5e79fbab-38be-4a64-94d5-867a94690932
Zeimpekis, Ioannis
a2c354ec-3891-497c-adac-89b3a5d96af0
Morgan, Katrina
2b9605fc-ac61-4ae7-b5f1-b6e3d257701d

Hackett, Charlotte, More, Yash, Komolafe, Abiodun, Zeimpekis, Ioannis and Morgan, Katrina (2026) Investigating the coupling between geometry and thermal gradient of flexible thermoelectric generators. Innovations in Large-Area Electronics, Cripps Court Conference Centre, Magdalene Colege, Cambridge, United Kingdom.

Record type: Conference or Workshop Item (Other)

Abstract

Flexible thermoelectric generators (f-TEGs) represent a promising technology for harvesting waste heat from ambient sources, including the human body, thereby enabling continuous power delivery for distributed sensors and wearable electronics [1]. However, their implementation as thin-film devices imposes inherent limitations on the achievable output power [2]. Since power generation scales with the number of thermoelectric units, large-area integration facilitated by a commercially viable roll-to-roll (R2R) manufacturing offers a practical route toward energy harvesting in applications such as electronic textiles [3]. Centimetre-scale f-TEGs incorporating multiple p–n pairs, typically on the order of several tens, have been shown to deliver power outputs in the nanowatt range [4]. Although device performance depends not only on electrical and thermal properties but also on geometry and the applied thermal gradient, the interplay among these factors is often underreported in experimental characterisations [5]. Consequently, reported values of output voltage and Seebeck coefficient can be inconsistent and difficult to compare across studies [6,7].

This work reports the characterisation of centimetre-scale f-TEGs, focusing on the influence of device geometry and thermal gradient on the measured open-circuit Seebeck voltage. Devices consisted of a 13 cm × 1 cm polyimide substrate with 12 p-n pairs of Bi₂Te₃ (n-type) and Sb₂Te₃ (p-type) thermoelectric legs connected electrically in series and thermally in parallel, as shown in Figure 1. The devices were mounted between heat sources, T1 and T2 supplied by Peltier modules under fixed input power, establishing a temperature gradient across the generator. The gradient was varied by adjusting the relative position of the Peltier modules to each other, introducing gaps of up to 10 mm along the device length. The open-circuit voltage was measured after 30 minutes of temperature stabilisation using a B1500A Semiconductor Device Analyzer by Aglient Technologies. Importantly, although the input power was fixed, the resulting temperature difference varied with gap configuration due to changes in heat transfer.
For all gap conditions, open-circuit voltage increased linearly with ΔT, which is the expected thermoelectric response described by the Seebeck coefficient, S=ΔV/ΔT , (Figure 2). However, the absolute voltage values varied markedly with the gap size. At a 10 mm gap, the device produced ~16 mV at ΔT ≈ 37 °C, while at full contact (0 mm gap), the voltage increased to ~34 mV at ΔT ≈ 34 °C, representing an increase of more than a factor of 2. This trend persisted across intermediate gap sizes: at ΔT ≈ 30 °C, output voltage consistently decreased with increasing gap size (Figure 3). This behaviour is unexpected, as the Seebeck coefficient is a material-intrinsic parameter and should remain constant for the same ΔT. These preliminary findings suggest that geometric configuration significantly affects thermal coupling and, consequently, the effective voltage response. Further studies are needed to isolate and confirm the mechanisms underlying this observation.

In conclusion, this work highlights the importance of the coupling between geometry and the thermal gradient of f-TEGs for maximising their open-circuit voltage. Optimised coupling will enable design of scalable devices for practical energy harvesting applications.

Text
Timetable+2026
Download (511kB)

More information

Published date: 19 February 2026
Venue - Dates: Innovations in Large-Area Electronics, Cripps Court Conference Centre, Magdalene Colege, Cambridge, United Kingdom, 2026-02-19

Identifiers

Local EPrints ID: 514211
URI: https://eprints.soton.ac.uk/id/eprint/514211
PURE UUID: 6f18fef0-fd9a-45ab-bc4d-4a1dea2ca296
ORCID for Abiodun Komolafe: ORCID iD orcid.org/0000-0002-3618-2390
ORCID for Ioannis Zeimpekis: ORCID iD orcid.org/0000-0002-7455-1599
ORCID for Katrina Morgan: ORCID iD orcid.org/0000-0002-8600-4322

Catalogue record

Date deposited: 09 Sep 2026 16:42
Last modified: 13 Sep 2026 15:51

Export record

Contributors

Author: Charlotte Hackett
Author: Yash More
Author: Abiodun Komolafe ORCID iD
Author: Katrina Morgan ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of https://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×