Limited-angle computed tomography: a simple approach to improve scan quality for high aspect-ratio fossils
Limited-angle computed tomography: a simple approach to improve scan quality for high aspect-ratio fossils
Fossils preserved on high aspect-ratio slabs of matrix (‘plate-like’ or ‘slab’ fossils with one short axis and two longer axes) include some of the most complete and scientifically significant vertebrate fossils ever discovered. These plate-like fossils are problematic to scan using conventional lab-based X-ray computed tomography (CT) for two reasons: 1) poor penetration of X-rays through the long, flat axis of the matrix slab leads to photon extinction imaging artefacts, and 2) resolution is limited by the distance required for the specimen to complete a full rotation avoiding collision with the X-ray source. One potential solution to these issues, which has yet to be thoroughly explored, is limited-angle computed tomography (LACT), a technique which involves rotating the specimen through an angle less than the full 360° typically used in lab-based CT. Here, we demonstrate LACT on a fossil specimen for the first time, highlighting the effects of adjusting angular sampling on scan quality. Although small angles of rotation result in significant imaging artefacts using conventional reconstruction methods (e.g., filtered back-projection), we find these artefacts are minimised at angles of rotation greater than 180°. The relative benefits of LACT are dependent on the purpose of the scan and the shape, size, and material of the specimen, with potential advantages including increased resolution and reduced photon extinction artefacts. We present scenarios in which using LACT over conventional CT to scan plate-like fossils should be considered, taking advantage of a relatively simple alteration to the scanning process to improve imaging results for these problematic specimens.
Crane, Abi
dc2dbf17-3c22-4a6d-9df8-88f03e5ef2dd
Alvarez-Borges, Fernando
5512cdfd-6ad3-475f-8aec-2fc767607314
Rankin, Kathryn
d9516566-0ad8-473d-b99b-4683c663a2b7
Clarkin, Claire
05cd2a88-1127-41aa-a29b-7ac323b4f3c9
Williams, Katherine
f1a55dba-1893-498c-b360-140a478620c1
Gostling, Neil
4840aa40-cb6c-4112-a0b9-694a869523fc
10 April 2026
Crane, Abi
dc2dbf17-3c22-4a6d-9df8-88f03e5ef2dd
Alvarez-Borges, Fernando
5512cdfd-6ad3-475f-8aec-2fc767607314
Rankin, Kathryn
d9516566-0ad8-473d-b99b-4683c663a2b7
Clarkin, Claire
05cd2a88-1127-41aa-a29b-7ac323b4f3c9
Williams, Katherine
f1a55dba-1893-498c-b360-140a478620c1
Gostling, Neil
4840aa40-cb6c-4112-a0b9-694a869523fc
Crane, Abi, Alvarez-Borges, Fernando, Rankin, Kathryn, Clarkin, Claire, Williams, Katherine and Gostling, Neil
(2026)
Limited-angle computed tomography: a simple approach to improve scan quality for high aspect-ratio fossils.
Palaeontologia Electronica, [29.1.a17].
(doi:10.26879/1621).
Abstract
Fossils preserved on high aspect-ratio slabs of matrix (‘plate-like’ or ‘slab’ fossils with one short axis and two longer axes) include some of the most complete and scientifically significant vertebrate fossils ever discovered. These plate-like fossils are problematic to scan using conventional lab-based X-ray computed tomography (CT) for two reasons: 1) poor penetration of X-rays through the long, flat axis of the matrix slab leads to photon extinction imaging artefacts, and 2) resolution is limited by the distance required for the specimen to complete a full rotation avoiding collision with the X-ray source. One potential solution to these issues, which has yet to be thoroughly explored, is limited-angle computed tomography (LACT), a technique which involves rotating the specimen through an angle less than the full 360° typically used in lab-based CT. Here, we demonstrate LACT on a fossil specimen for the first time, highlighting the effects of adjusting angular sampling on scan quality. Although small angles of rotation result in significant imaging artefacts using conventional reconstruction methods (e.g., filtered back-projection), we find these artefacts are minimised at angles of rotation greater than 180°. The relative benefits of LACT are dependent on the purpose of the scan and the shape, size, and material of the specimen, with potential advantages including increased resolution and reduced photon extinction artefacts. We present scenarios in which using LACT over conventional CT to scan plate-like fossils should be considered, taking advantage of a relatively simple alteration to the scanning process to improve imaging results for these problematic specimens.
This record has no associated files available for download.
More information
Accepted/In Press date: 9 April 2026
Published date: 10 April 2026
Identifiers
Local EPrints ID: 514654
URI: https://eprints.soton.ac.uk/id/eprint/514654
ISSN: 1935-3952
PURE UUID: e696231c-5799-415f-97b8-f0bc52810586
Catalogue record
Date deposited: 22 Sep 2026 16:43
Last modified: 23 Oct 2026 01:50
Export record
Altmetrics
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics