The University of Southampton
University of Southampton Institutional Repository

Modelling and optimisation of microfluidic devices for bioanalysis applications

Modelling and optimisation of microfluidic devices for bioanalysis applications
Modelling and optimisation of microfluidic devices for bioanalysis applications
The small size of integrated microfluidic systems offers many advantages such as cost, speed and portability for bioanalysis applications. However, due to the small scale the careful consideration of the transport of analytes in the bulk of the integrated microfluidic system and the interaction of analytes with surface immobilised analyte recognition molecules (receptors) is crucial for an efficient device operation. This thesis is concerned with the mathematical analysis and optimisation of the convective and diffusive transport of analytes and the analyte-receptor interaction in integrated microfluidic affinity systems with the aim of creating design guidelines for more efficient bioanalysis systems.

The first part of this thesis considers device configurations where every analyte molecule can reach the surface immobilised receptors. In this case, which is important for sensing and separation applications, the transport-reaction model is solved analytically. This analytical solution is analysed for two bioanalytical applications: (i) affinity separation and (ii) affinity sensing. For fast analyte-receptor interactions, which are essential for affinity separation systems, the analysis of the analytical solution reveals simple expressions for the retention and the dispersion of the analyte due to the interaction with the receptors. With these expressions, which depend only on global device parameters, a framework for the design of multiplexed separation systems for the separation of proteins from complex sample mixtures is developed. Subsequently, the analytical solution of the transport-reaction model is used in the derivation of improved design strategies for microfluidic affinity sensors for the detection of analytes from small sample plugs. Three design strategies, which achieve a high capture fraction and a significantly increased uniformity of the bound analyte concentration over the sensor surface, are presented. The first two strategies rely on the variation of one device parameter, i.e. the flow velocity or the surface immobilised receptor concentration, as the analyte plug is flowed through the channel. The third approach is based on non-rectangular devices where the analyte plug is replenished by a narrowing of the flow channel. This third design strategy is applied to the redesign of a biosensor for the detection of low cytokine levels from small sample volumes.

In the second part a novel microfluidic system for the generation of concentration gradients across microfluidic channels is developed. In this design the analytes are transported by surface groove induced secondary flow from the source to the sink stream. Numerical optimisations over the shape and size of the surface groove result in gradient generators which yield a well-defined linear or exponential concentration gradient across the width of the microfluidic channel. The resulting gradient generators have a much smaller footprint than conventional gradient generators and are thus more suitable for highly integrated lab-on-a-chip systems.
Friedrich, Daniel
38fec5ed-5104-4d67-9354-2e064d0bdad2
Friedrich, Daniel
38fec5ed-5104-4d67-9354-2e064d0bdad2
Melvin, T.
fd87f5eb-2bb9-48fa-b7be-7100ace9c50f

Friedrich, Daniel (2009) Modelling and optimisation of microfluidic devices for bioanalysis applications. University of Southampton, Optoelectronics Research Centre, Doctoral Thesis, 292pp.

Record type: Thesis (Doctoral)

Abstract

The small size of integrated microfluidic systems offers many advantages such as cost, speed and portability for bioanalysis applications. However, due to the small scale the careful consideration of the transport of analytes in the bulk of the integrated microfluidic system and the interaction of analytes with surface immobilised analyte recognition molecules (receptors) is crucial for an efficient device operation. This thesis is concerned with the mathematical analysis and optimisation of the convective and diffusive transport of analytes and the analyte-receptor interaction in integrated microfluidic affinity systems with the aim of creating design guidelines for more efficient bioanalysis systems.

The first part of this thesis considers device configurations where every analyte molecule can reach the surface immobilised receptors. In this case, which is important for sensing and separation applications, the transport-reaction model is solved analytically. This analytical solution is analysed for two bioanalytical applications: (i) affinity separation and (ii) affinity sensing. For fast analyte-receptor interactions, which are essential for affinity separation systems, the analysis of the analytical solution reveals simple expressions for the retention and the dispersion of the analyte due to the interaction with the receptors. With these expressions, which depend only on global device parameters, a framework for the design of multiplexed separation systems for the separation of proteins from complex sample mixtures is developed. Subsequently, the analytical solution of the transport-reaction model is used in the derivation of improved design strategies for microfluidic affinity sensors for the detection of analytes from small sample plugs. Three design strategies, which achieve a high capture fraction and a significantly increased uniformity of the bound analyte concentration over the sensor surface, are presented. The first two strategies rely on the variation of one device parameter, i.e. the flow velocity or the surface immobilised receptor concentration, as the analyte plug is flowed through the channel. The third approach is based on non-rectangular devices where the analyte plug is replenished by a narrowing of the flow channel. This third design strategy is applied to the redesign of a biosensor for the detection of low cytokine levels from small sample volumes.

In the second part a novel microfluidic system for the generation of concentration gradients across microfluidic channels is developed. In this design the analytes are transported by surface groove induced secondary flow from the source to the sink stream. Numerical optimisations over the shape and size of the surface groove result in gradient generators which yield a well-defined linear or exponential concentration gradient across the width of the microfluidic channel. The resulting gradient generators have a much smaller footprint than conventional gradient generators and are thus more suitable for highly integrated lab-on-a-chip systems.

Text
Daniel_Friedrich_Thesis_Revised_Final_20100518.pdf - Accepted Manuscript
Available under License University of Southampton Thesis Licence.
Download (4MB)

More information

Published date: November 2009
Organisations: University of Southampton, Optoelectronics Research Centre

Identifiers

Local EPrints ID: 301284
URI: http://eprints.soton.ac.uk/id/eprint/301284
PURE UUID: b22e5532-8aa2-4358-b6ee-f2c9b5a48efb

Catalogue record

Date deposited: 02 Apr 2012 13:49
Last modified: 14 Mar 2024 10:28

Export record

Contributors

Author: Daniel Friedrich
Thesis advisor: T. Melvin

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×