Thick-Film planar solid-state Silver/Silver Chloride (Ag/AgCl) reference electrodes were developed and tested for ion susceptibility and long term drift in approximately 0.04 M potassium chloride (KCl) solution. Various types of electrodes were tested exhibiting stabilities down to 2 millivolts per decade change of chloride concentration. It is demonstrated that Thick-Film reference electrodes are suitable for use in underground soil measurements due to their ruggedness and robustness.