Measurement of Leakage Current at the Oil-Pressboard Interface during Surface Discharge
Measurement of Leakage Current at the Oil-Pressboard Interface during Surface Discharge
Surface discharge at the oil-pressboard interface is classified as one of the most dangerous fault conditions of large transformers. Surface discharges can be sustained for long periods without surface flashover or breakdown as long as the surface breakdown voltage is not exceeded [1]. Damage at the pressboard surface due to surface discharge is a function of applied voltage and time. If an applied voltage, above the surface partial discharge inception voltage (PDIV) but less than surface flashover voltage persists, the resulting discharges can develop a creeping path due to the drying out of the pressboard by localized heating (forcing oil and water out of the pressboard pores) and the carbonization of the oil and cellulose [1]. The drying of pressboard during the surface discharge process has been observed as the development of white marks on the pressboard surface [1]. A surface discharge experiment using a needle-bar electrode configuration has been developed. A shunt resistor that has been extensively used to measure leakage current for outdoor insulation systems [2] is used in the experiment. The leakage current is also measured using a commercial partial discharge detection system to allow comparison of the leakage current waveform from the oscilloscope against the corresponding phase resolved partial discharge (PRPD) pattern obtained. Figure 1 shows an example of measured leakage current during the occurrence of full-length discharge. It has been found that after long periods of surface discharge, temporary full-length discharges may occur across the pressboard surface bridging the needle tip and the earth without resulting in complete electrical breakdown. The full-length discharges occur when the white marks have reached the earth bar and travel along the same path as the white marks [3]. The occurrence of this full-length discharge leads to small leakage current (mA range) flowing to earth that is unlikely to trip the earth fault protection relays [3]. Although the currents are relatively small, identifying their presence and relating them to forms of PD activity at the pressboard oil interface is important as it may provide a mechanism for earlier detection of creep stress failure.
24
Zainuddin, H
c9e0665b-ea0b-4a65-9f53-49d90f66cd8c
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Mitchinson, P M
9de2f4d4-38fb-466b-94c6-c4390a6b2aa8
18 January 2012
Zainuddin, H
c9e0665b-ea0b-4a65-9f53-49d90f66cd8c
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Mitchinson, P M
9de2f4d4-38fb-466b-94c6-c4390a6b2aa8
Zainuddin, H, Lewin, P L and Mitchinson, P M
(2012)
Measurement of Leakage Current at the Oil-Pressboard Interface during Surface Discharge.
The Fifth UHVnet Colloquium, University of Leicester, Leicester, United Kingdom.
18 - 19 Jan 2012.
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
Surface discharge at the oil-pressboard interface is classified as one of the most dangerous fault conditions of large transformers. Surface discharges can be sustained for long periods without surface flashover or breakdown as long as the surface breakdown voltage is not exceeded [1]. Damage at the pressboard surface due to surface discharge is a function of applied voltage and time. If an applied voltage, above the surface partial discharge inception voltage (PDIV) but less than surface flashover voltage persists, the resulting discharges can develop a creeping path due to the drying out of the pressboard by localized heating (forcing oil and water out of the pressboard pores) and the carbonization of the oil and cellulose [1]. The drying of pressboard during the surface discharge process has been observed as the development of white marks on the pressboard surface [1]. A surface discharge experiment using a needle-bar electrode configuration has been developed. A shunt resistor that has been extensively used to measure leakage current for outdoor insulation systems [2] is used in the experiment. The leakage current is also measured using a commercial partial discharge detection system to allow comparison of the leakage current waveform from the oscilloscope against the corresponding phase resolved partial discharge (PRPD) pattern obtained. Figure 1 shows an example of measured leakage current during the occurrence of full-length discharge. It has been found that after long periods of surface discharge, temporary full-length discharges may occur across the pressboard surface bridging the needle tip and the earth without resulting in complete electrical breakdown. The full-length discharges occur when the white marks have reached the earth bar and travel along the same path as the white marks [3]. The occurrence of this full-length discharge leads to small leakage current (mA range) flowing to earth that is unlikely to trip the earth fault protection relays [3]. Although the currents are relatively small, identifying their presence and relating them to forms of PD activity at the pressboard oil interface is important as it may provide a mechanism for earlier detection of creep stress failure.
Text
HidayatPoster.pdf
- Other
Text
UHVnet2012_abstract-UoS_Hidayat.pdf
- Version of Record
More information
Published date: 18 January 2012
Additional Information:
Event Dates: 18-19 January 2012
Venue - Dates:
The Fifth UHVnet Colloquium, University of Leicester, Leicester, United Kingdom, 2012-01-18 - 2012-01-19
Organisations:
Electronics & Computer Science, EEE
Identifiers
Local EPrints ID: 273127
URI: http://eprints.soton.ac.uk/id/eprint/273127
PURE UUID: 2ce42a52-44b9-4b0f-b80b-e773e1f0c4b4
Catalogue record
Date deposited: 20 Jan 2012 14:56
Last modified: 15 Mar 2024 02:43
Export record
Contributors
Author:
H Zainuddin
Author:
P L Lewin
Author:
P M Mitchinson
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics