The University of Southampton
University of Southampton Institutional Repository

Investigation of wear and corrosion products from around explanted CoCrMo tapers

Investigation of wear and corrosion products from around explanted CoCrMo tapers
Investigation of wear and corrosion products from around explanted CoCrMo tapers
Metallic contacts in hip replacements are susceptible to wear and corrosion processes which lead to the release of particles and metal ions. Adverse local tissue reactions (ALTRs) and systemic manifestations to solid and soluble debris can be debilitating for the patients. It is believed that particles originating from CoCrMo taper junctions trigger more severe body reactions compared to debris from MoM hip bearings. The body’s reaction is highly dependent on particle characteristics, such as size, morphology, composition and aggregation state, which can reflect the specific wear and corrosion conditions at the site of release. Here we proposed to investigate wear and corrosion flakes collected from around CoCrMo tapers at the time of revision. The particles were initially characterised with scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). This revealed the microstructure of the corrosion products, which appeared to be made of smaller metallic aggregates, entrapped in a biological matrix. The in depth characterisation of the particles released from the organo-metallic composite, was performed with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM), both fitted with EDX. The investigation revealed clusters and individual nanoparticles, as small as 3 nm, which represent the building blocks of the large corrosion flakes, reported and characterised in the past mainly with low resolution microscopy techniques. The majority of the particles consisted of Cr and O, potentially in the form of chromium oxides, with little evidence of Co and Mo. Particles size distribution (PSD) provided by STEM and TEM characterisation showed statistically different results. The STEM technique was able to resolve tiny particles found in close proximity and provided a PSD shift towards the smaller end of the size range. The study is the first to show microscopy evidence of Cr rich nanoparticles (3-60 nm) released in vivo from the modular taper interface, which can have important health implications caused by their increased potential to disseminate and corrode within the body.
Crainic, Alina-Mariana
a8df3e5f-a738-4683-acc8-c75433c88cd0
Callisti, Mauro
b925d711-b012-4c01-8a70-fe7bd59d30c9
Palmer, Martin
d2e60e81-5d6e-4ddb-a243-602537286080
Cook, Richard
06f8322d-81be-4f82-9326-19e55541c78f
Crainic, Alina-Mariana
a8df3e5f-a738-4683-acc8-c75433c88cd0
Callisti, Mauro
b925d711-b012-4c01-8a70-fe7bd59d30c9
Palmer, Martin
d2e60e81-5d6e-4ddb-a243-602537286080
Cook, Richard
06f8322d-81be-4f82-9326-19e55541c78f

Crainic, Alina-Mariana, Callisti, Mauro, Palmer, Martin and Cook, Richard (2017) Investigation of wear and corrosion products from around explanted CoCrMo tapers. British Hip Society Annual Scientific Meeting, Central Hall Westminster, London, United Kingdom. 01 - 03 Mar 2017.

Record type: Conference or Workshop Item (Paper)

Abstract

Metallic contacts in hip replacements are susceptible to wear and corrosion processes which lead to the release of particles and metal ions. Adverse local tissue reactions (ALTRs) and systemic manifestations to solid and soluble debris can be debilitating for the patients. It is believed that particles originating from CoCrMo taper junctions trigger more severe body reactions compared to debris from MoM hip bearings. The body’s reaction is highly dependent on particle characteristics, such as size, morphology, composition and aggregation state, which can reflect the specific wear and corrosion conditions at the site of release. Here we proposed to investigate wear and corrosion flakes collected from around CoCrMo tapers at the time of revision. The particles were initially characterised with scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). This revealed the microstructure of the corrosion products, which appeared to be made of smaller metallic aggregates, entrapped in a biological matrix. The in depth characterisation of the particles released from the organo-metallic composite, was performed with transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM), both fitted with EDX. The investigation revealed clusters and individual nanoparticles, as small as 3 nm, which represent the building blocks of the large corrosion flakes, reported and characterised in the past mainly with low resolution microscopy techniques. The majority of the particles consisted of Cr and O, potentially in the form of chromium oxides, with little evidence of Co and Mo. Particles size distribution (PSD) provided by STEM and TEM characterisation showed statistically different results. The STEM technique was able to resolve tiny particles found in close proximity and provided a PSD shift towards the smaller end of the size range. The study is the first to show microscopy evidence of Cr rich nanoparticles (3-60 nm) released in vivo from the modular taper interface, which can have important health implications caused by their increased potential to disseminate and corrode within the body.

Text
BHS abstract Alina Crainic - Author's Original
Download (14kB)
Text
BHS Presentation - Accepted Manuscript
Download (1MB)

More information

Published date: 1 March 2017
Venue - Dates: British Hip Society Annual Scientific Meeting, Central Hall Westminster, London, United Kingdom, 2017-03-01 - 2017-03-03

Identifiers

Local EPrints ID: 414350
URI: http://eprints.soton.ac.uk/id/eprint/414350
PURE UUID: 3cccf43b-cfec-4f55-b835-baedc84ca81d
ORCID for Richard Cook: ORCID iD orcid.org/0000-0002-2468-5820

Catalogue record

Date deposited: 27 Sep 2017 16:30
Last modified: 16 Mar 2024 04:01

Export record

Contributors

Author: Alina-Mariana Crainic
Author: Mauro Callisti
Author: Martin Palmer
Author: Richard Cook ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×