The University of Southampton
University of Southampton Institutional Repository

Long-term self-noise estimates of seismic sensors from high-noise vault installations

Long-term self-noise estimates of seismic sensors from high-noise vault installations
Long-term self-noise estimates of seismic sensors from high-noise vault installations
To understand the detection capabilities of seismic stations and for reducing biases in ambient noise imaging, it is vital to assess the contribution of instrument self-noise to overall site noise. Self-noise estimates typically come from vault installations in continental interiors with very low ambient noise levels. However, this approach restricts the independent assessment of self-noise by individual end-users to assess any variations in their own instrument pools from nominal specifications given by manufacturers and from estimations given in comparative test papers. However, the calculation method should be adapted to variable installation conditions. One problem is that microseism noise can contaminate self-noise results caused by instrument misalignment errors or manufacturing limits; this effect becomes stronger where ambient noise is higher. Moreover, due to expected stochastic and time-varying sensor noise, estimates based on hand-picking small numbers of data segments may not accurately reflect true self-noise. We report on results from a self-noise test experiment of Güralp seismic instruments (3T, 3ESPC broadband seismometers, Fortis strong motion accelerometer) that were installed in the sub-surface vault of the Eskdalemuir Seismic Observatory in Scotland, UK over the period October 2016–August 2017. Due to vault’s proximity to the ocean, secondary microseism noise is strong, so we efficiently compute the angle of misalignment that maximises waveform coherence with a reference sensor. Self-noise was calculated using the 3-sensor correlation technique and we compute probability density functions of self-noise to assess its spread over time. We find that not correcting for misalignments as low as 0.1° can cause self-noise to be artificially higher by up to ~15 dB at frequencies of 0.1-1 Hz. Our method thus efficiently removes the effect of microseism contamination on self-noise; for example, it restores the minimum noise floor for a 360s – 50 Hz 3T to -195 dB at 0.2 Hz. Furthermore, based on the analysis of our calculated probability density functions, we find at long-periods (> 30 s) the average self-noise can be up to 5 dB higher than the minimum noise floor. We discuss the validity of these results in terms of making direct comparisons with self-noise results from much quieter installations.
Hicks, Stephen
036d1b3b-bb7a-4a22-b2ce-71618a1723a3
Rietbrock, Andreas
9fbc63af-9a9a-4dfe-a389-83d92b5f4cc2
Goessen, Shawn
7d9a904b-d3bf-4923-8822-78c513d9e5d2
Hill, Phil
06eb3b43-e523-42a6-b976-f07e01a19f3a
Hicks, Stephen
036d1b3b-bb7a-4a22-b2ce-71618a1723a3
Rietbrock, Andreas
9fbc63af-9a9a-4dfe-a389-83d92b5f4cc2
Goessen, Shawn
7d9a904b-d3bf-4923-8822-78c513d9e5d2
Hill, Phil
06eb3b43-e523-42a6-b976-f07e01a19f3a

Hicks, Stephen, Rietbrock, Andreas, Goessen, Shawn and Hill, Phil (2017) Long-term self-noise estimates of seismic sensors from high-noise vault installations. In AGU Fall Meeting 2017.

Record type: Conference or Workshop Item (Paper)

Abstract

To understand the detection capabilities of seismic stations and for reducing biases in ambient noise imaging, it is vital to assess the contribution of instrument self-noise to overall site noise. Self-noise estimates typically come from vault installations in continental interiors with very low ambient noise levels. However, this approach restricts the independent assessment of self-noise by individual end-users to assess any variations in their own instrument pools from nominal specifications given by manufacturers and from estimations given in comparative test papers. However, the calculation method should be adapted to variable installation conditions. One problem is that microseism noise can contaminate self-noise results caused by instrument misalignment errors or manufacturing limits; this effect becomes stronger where ambient noise is higher. Moreover, due to expected stochastic and time-varying sensor noise, estimates based on hand-picking small numbers of data segments may not accurately reflect true self-noise. We report on results from a self-noise test experiment of Güralp seismic instruments (3T, 3ESPC broadband seismometers, Fortis strong motion accelerometer) that were installed in the sub-surface vault of the Eskdalemuir Seismic Observatory in Scotland, UK over the period October 2016–August 2017. Due to vault’s proximity to the ocean, secondary microseism noise is strong, so we efficiently compute the angle of misalignment that maximises waveform coherence with a reference sensor. Self-noise was calculated using the 3-sensor correlation technique and we compute probability density functions of self-noise to assess its spread over time. We find that not correcting for misalignments as low as 0.1° can cause self-noise to be artificially higher by up to ~15 dB at frequencies of 0.1-1 Hz. Our method thus efficiently removes the effect of microseism contamination on self-noise; for example, it restores the minimum noise floor for a 360s – 50 Hz 3T to -195 dB at 0.2 Hz. Furthermore, based on the analysis of our calculated probability density functions, we find at long-periods (> 30 s) the average self-noise can be up to 5 dB higher than the minimum noise floor. We discuss the validity of these results in terms of making direct comparisons with self-noise results from much quieter installations.

Text
AGU2017_SelfNoisePoster_SHicks_final - Author's Original
Download (6MB)

More information

Published date: 2017

Identifiers

Local EPrints ID: 416697
URI: http://eprints.soton.ac.uk/id/eprint/416697
PURE UUID: 701dc1b8-1831-4295-84c0-5e501fca6c3c
ORCID for Stephen Hicks: ORCID iD orcid.org/0000-0002-7476-3284

Catalogue record

Date deposited: 05 Jan 2018 17:30
Last modified: 15 Mar 2024 17:45

Export record

Contributors

Author: Stephen Hicks ORCID iD
Author: Andreas Rietbrock
Author: Shawn Goessen
Author: Phil Hill

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×