The University of Southampton
University of Southampton Institutional Repository

Archaeological detection by resistivity

Archaeological detection by resistivity
Archaeological detection by resistivity

A brief history is given of the development of resistivity detection in archaeology, followed by an outline of basic principles and theory, and of the evolution of the Martin-Clark resistivity meters, including circuit diagrams.The chief outstanding problems are identified as choice of the most I suitable probe configurations, climatic water balance effects, and speed i of working. For studying the configuration problem, the design of a rapidly operating automatic electrolytic tank system is detailed, together with a set of simulated archaeological features. Ten configurations are examined, of which the Twin-Electrode, Double Dipole and Square Array are found most effective, with the addition of Wenner for selected purposes. The Triple Electrode also appears promising. For the climate study, fixed tiaterse lines were established across three silted up ditches of known profile and widely varied size on Upper Chalk in southern England, and measured monthly for 19 months. The pattern of resistivity response with water balance differed greatly according to ditch size. The data, and results obtained by others for Triassic sandstone, London Clay and limestone are collated, and guidelines for interpretation and the choice of optimum survey times, probe configurations and spacings established. Some analysis of the related phenomenon of crop mark production is appended. In combination, the tank and climate studies show that the resistivity anomalies caused by many archaeological features approximate to a horizontal high resistivity lamina. Examples of surveys using the optimum configurations are given, the results being compared with those of magnetic surveys where possible; methods of plotting and processing the data are also compared. Some high performance survey systems incorporating results from this research are described.

University of Southampton
Clark, Anthony John
71dabe1c-5b9b-4cda-8ce6-30b0e11dfbda
Clark, Anthony John
71dabe1c-5b9b-4cda-8ce6-30b0e11dfbda

Clark, Anthony John (1980) Archaeological detection by resistivity. University of Southampton, Doctoral Thesis.

Record type: Thesis (Doctoral)

Abstract

A brief history is given of the development of resistivity detection in archaeology, followed by an outline of basic principles and theory, and of the evolution of the Martin-Clark resistivity meters, including circuit diagrams.The chief outstanding problems are identified as choice of the most I suitable probe configurations, climatic water balance effects, and speed i of working. For studying the configuration problem, the design of a rapidly operating automatic electrolytic tank system is detailed, together with a set of simulated archaeological features. Ten configurations are examined, of which the Twin-Electrode, Double Dipole and Square Array are found most effective, with the addition of Wenner for selected purposes. The Triple Electrode also appears promising. For the climate study, fixed tiaterse lines were established across three silted up ditches of known profile and widely varied size on Upper Chalk in southern England, and measured monthly for 19 months. The pattern of resistivity response with water balance differed greatly according to ditch size. The data, and results obtained by others for Triassic sandstone, London Clay and limestone are collated, and guidelines for interpretation and the choice of optimum survey times, probe configurations and spacings established. Some analysis of the related phenomenon of crop mark production is appended. In combination, the tank and climate studies show that the resistivity anomalies caused by many archaeological features approximate to a horizontal high resistivity lamina. Examples of surveys using the optimum configurations are given, the results being compared with those of magnetic surveys where possible; methods of plotting and processing the data are also compared. Some high performance survey systems incorporating results from this research are described.

Text
453902.pdf - Version of Record
Available under License University of Southampton Thesis Licence.
Download (6MB)

More information

Published date: 1980

Identifiers

Local EPrints ID: 462734
URI: http://eprints.soton.ac.uk/id/eprint/462734
PURE UUID: 6908cd03-db82-4301-9685-bb2641e522ae

Catalogue record

Date deposited: 04 Jul 2022 19:49
Last modified: 16 Mar 2024 18:58

Export record

Contributors

Author: Anthony John Clark

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×