Dataset in support of the Southampton doctoral thesis 'MIR photodetection using intrinsic monolithic integrated germanium photodiodes'
Dataset in support of the Southampton doctoral thesis 'MIR photodetection using intrinsic monolithic integrated germanium photodiodes'
This dataset contains: Data underpinning the tables and figures in the thesis
Tab 1 – GC Losses
These tables provide the data used to calculate the grating coupler losses for Table 7.1 in the thesis.
Loss of the grating coupler is calculated as.
Loss = 10*Log(Power_In/Power_Out)
Tab 2 – GC Losses 3.8um
These tables have the data used to calculate the GC losses at 3.8um for Fig 3.8
Tab 3 – 2um Prop Loss
These tables have the data used to calculate the propagation loss of the waveguides using 2um light. Seen in figure 7.4
Tab 4 – 3.8um Prop Loss
These tables have the data used to calculate the propagation loss of the waveguides using 3.8um light. Seen in figure 7.5
Tab 5 – 0V Resp
This is the data used for figure 7.7.
Tab 6 – IV Curve 2um
This data is used for figure 7.8
Tab 7 – IV Curve 3.8um
This data is used for figure 7.10
Tab 8 – VNA Freq
This data is used for figure 7.12
Tab 9 – Linearity
This data is used for figure 7.15
Tab 10 – Raman Graph
This data is used for figure 7.16
University of Southampton
Reid, Lauren
0a08167e-38b2-4418-8229-183cf35b0716
Reid, Lauren
0a08167e-38b2-4418-8229-183cf35b0716
Reid, Lauren
(2022)
Dataset in support of the Southampton doctoral thesis 'MIR photodetection using intrinsic monolithic integrated germanium photodiodes'.
University of Southampton
doi:10.5258/SOTON/D2430
[Dataset]
Abstract
This dataset contains: Data underpinning the tables and figures in the thesis
Tab 1 – GC Losses
These tables provide the data used to calculate the grating coupler losses for Table 7.1 in the thesis.
Loss of the grating coupler is calculated as.
Loss = 10*Log(Power_In/Power_Out)
Tab 2 – GC Losses 3.8um
These tables have the data used to calculate the GC losses at 3.8um for Fig 3.8
Tab 3 – 2um Prop Loss
These tables have the data used to calculate the propagation loss of the waveguides using 2um light. Seen in figure 7.4
Tab 4 – 3.8um Prop Loss
These tables have the data used to calculate the propagation loss of the waveguides using 3.8um light. Seen in figure 7.5
Tab 5 – 0V Resp
This is the data used for figure 7.7.
Tab 6 – IV Curve 2um
This data is used for figure 7.8
Tab 7 – IV Curve 3.8um
This data is used for figure 7.10
Tab 8 – VNA Freq
This data is used for figure 7.12
Tab 9 – Linearity
This data is used for figure 7.15
Tab 10 – Raman Graph
This data is used for figure 7.16
Text
readme.txt
- Dataset
Spreadsheet
data.xlsx
- Dataset
More information
Published date: 2022
Identifiers
Local EPrints ID: 478717
URI: http://eprints.soton.ac.uk/id/eprint/478717
PURE UUID: 59de5384-f184-48aa-ab8b-18e0a405e443
Catalogue record
Date deposited: 07 Jul 2023 16:44
Last modified: 07 Jul 2023 16:44
Export record
Altmetrics
Contributors
Creator:
Lauren Reid
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics